1. Put the system into disarmed mode.
2. Loosen the cover fixing screw using a Philips screwdriver and detach the cover from the base.
3. Take out the old battery and press any key twice to discharge before replacing the new battery in the battery
compartment. Please note the polarity of the battery when fitting in.
4. Reattach the cover to the base and tighten the cover fixing screw using a Philips screwdriver.
l
l
T
T
a
a
m
m
p
p
e
e
r
r
P
P
r
r
o
o
t
t
e
e
c
c
t
t
i
i
o
o
n
n
l
The tamper switch is compressed against the mounting surface when the Keypad is properly installed. When the
keypad is removed from installed location or when the cover is opened, the tamper switch will be triggered and the
Keypad will transmit a tamper open signal to the ZigBee network coordinator or system control panel.
l
The Tamper switch will only be activated 5 minutes after joining a ZigBee network.
l
If tamper protection is violated, tamper protection will only be activated again 5 minutes after the tamper is restored.
ZigBee Network Setup
l
l
Z
Z
i
i
g
g
B
B
e
e
e
e
D
D
e
e
v
v
i
i
c
c
e
e
G
G
u
u
i
i
d
d
e
e
l
l
i
i
n
n
e
e
ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission
efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and
coordinated for data exchange and signal transmission.
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on.
Since performing a task in connecting network may consume some power, it is required to follow the instructions to avoid
draining battery of a ZigBee device
- Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee device.
- Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use.
- Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a ZigBee
device.
l
l
J
J
o
o
i
i
n
n
i
i
n
n
g
g
t
t
h
h
e
e
Z
Z
i
i
g
g
B
B
e
e
e
e
N
N
e
e
t
t
w
w
o
o
r
r
k
k
As a ZigBee device, the Keypad needs to join a ZigBee network to transmit and receive signal. Please follow the steps
below to join the device into the ZigBee network.
1. Pull out the Battery Insulator to activate the battery.
2. Press and hold the Disarm key for 10 seconds, release the button when the Keypad emits 2 beeps and the ZigBee
Network LED will flash once. The Keypad will reset and scan for an existing ZigBee network. Please make sure to
enable the permit-join feature on the router or coordinator of your ZigBee network.
3. After joining the ZigBee network, the ZigBee Network LED will flash twice the Keypad will emit one long beep and it
will be registered in the security system in the network automatically. Please check the ZigBee network coordinator,
system control panel, or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful.
4. The Keypad will not emit any sounds if it did not join the ZigBee network. Please check your ZigBee network
coordinator, control panel or CIE setting to ensure the permit-join function is available, and then use the Factory
Reset function below to join the ZigBee network.
l
l
R
R
e
e
m
m
o
o
v
v
i
i
n
n
g
g
D
D
e
e
v
v
i
i
c
c
e
e
f
f
r
r
o
o
m
m
Z
Z
i
i
g
g
B
B
e
e
e
e
N
N
e
e
t
t
w
w
o
o
r
r
k
k
(
(
F
F
a
a
c
c
t
t
o
o
r
r
y
y
R
R
e
e
s
s
e
e
t
t
)
)
To remove the Keypad from current ZigBee network, the Keypad must be put to Factory Reset to complete device removal.
Factory Reset function will clear the device of its stored setting information and prompt the Keypad to search for new ZigBee
network.
Before removing device, make sure the Keypad is within current ZigBee network signal range
1. Press and hold the function button for 10 seconds, then release the button to reset Keypad.
2. Upon reset, the Keypad will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove
itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network
automatically.
Installation
l
l
M
M
o
o
u
u
n
n
t
t
i
i
n
n
g
g
t
t
h
h
e
e
R
R
e
e
m
m
o
o
t
t
e
e
K
K
e
e
y
y
p
p
a
a
d
d
To mount the remote keypad:
1. Remove the front cover by loosening the cover fixing screw using a Philips screwdriver.
2. Using the 2 mounting holes of the base as a template, mark off the positions in the most appropriate place.
3. Insert the wall plugs if fixing into plaster or brick surface.
4. Screw the base onto the wall plugs using a Philips screwdriver.
5. Replace the front cover and tighten the cover fixing screw using a Philips screwdriver.
l
l
U
U
s
s
i
i
n
n
g
g
R
R
e
e
m
m
o
o
t
t
e
e
k
k
e
e
y
y
p
p
a
a
d
d
w
w
i
i
t
t
h
h
Z
Z
i
i
g
g
B
B
e
e
e
e
R
R
o
o
u
u
t
t
e
e
r
r
IMPORTANT NOTE
If the Remote keypad installation location is away from your system control panel and requires ZigBee routers to improve
signal strength.
DO NOT
use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down
during AC power failure and the Remote keypad connected to the router will lose connection with ZigBee network. You
should plan your Remote keypad installation location using only ZigBee router with backup battery.