1.  Put the system into disarmed mode. 
2.  Loosen the cover fixing screw using a Philips screwdriver and detach the cover from the base. 
3.  Take  out  the  old  battery  and  press  any  key  twice  to  discharge  before  replacing  the  new  battery  in  the  battery 

compartment. Please note the polarity of the battery when fitting in. 

4.  Reattach the cover to the base and tighten the cover fixing screw using a Philips screwdriver.   

l

l

 

 

T

T

a

a

m

m

p

p

e

e

r

r

 

 

P

P

r

r

o

o

t

t

e

e

c

c

t

t

i

i

o

o

n

n

 

 

l

 

The  tamper  switch  is  compressed  against  the  mounting  surface  when  the  Keypad  is  properly  installed.  When  the 
keypad is removed from installed location or when the cover  is  opened,  the  tamper  switch  will  be  triggered  and  the 
Keypad will transmit a tamper open signal to the ZigBee network coordinator or system control panel. 

l

 

The Tamper switch will only be activated 5 minutes after joining a ZigBee network. 

l

 

If tamper protection is violated, tamper protection will only be activated again 5 minutes after the tamper is restored. 

 

ZigBee Network Setup 

l

l

 

 

Z

Z

i

i

g

g

B

B

e

e

e

e

 

 

D

D

e

e

v

v

i

i

c

c

e

e

 

 

G

G

u

u

i

i

d

d

e

e

l

l

i

i

n

n

e

e

 

 

ZigBee is a wireless communication protocol that is reliable, has low power consumption and has high transmission 
efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and 
coordinated for data exchange and signal transmission. 
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on. 
Since performing a task in connecting network may consume some power, it is required to follow the instructions to avoid 
draining battery of a ZigBee device 

- Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee device. 
- Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use. 
- Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a ZigBee 

device. 

l

l

 

 

J

J

o

o

i

i

n

n

i

i

n

n

g

g

 

 

t

t

h

h

e

e

 

 

Z

Z

i

i

g

g

B

B

e

e

e

e

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

As a ZigBee device, the Keypad needs to join a ZigBee network to transmit and receive signal. Please follow the steps 
below to join the device into the ZigBee network. 

1.  Pull out the Battery Insulator to activate the battery. 
2.  Press and hold the Disarm key for 10 seconds, release the button when the Keypad emits 2 beeps and the ZigBee 

Network LED will flash once. The Keypad will reset and scan for an existing ZigBee network. Please make sure to 
enable the permit-join feature on the router or coordinator of your ZigBee network. 

3.  After joining the ZigBee network, the ZigBee Network LED will flash twice the Keypad will emit one long beep and it 

will be registered in the security system in the network automatically. Please check the ZigBee network coordinator, 
system control panel, or CIE (Control and Indicating Equipment) to confirm if joining and registration is successful. 

4.  The  Keypad  will  not  emit  any  sounds  if  it  did  not  join  the  ZigBee  network.  Please  check  your  ZigBee  network 

coordinator,  control  panel  or  CIE  setting  to  ensure  the  permit-join  function  is  available,  and  then  use  the  Factory 
Reset function below to join the ZigBee network. 

l

l

 

 

R

R

e

e

m

m

o

o

v

v

i

i

n

n

g

g

 

 

D

D

e

e

v

v

i

i

c

c

e

e

 

 

f

f

r

r

o

o

m

m

 

 

Z

Z

i

i

g

g

B

B

e

e

e

e

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

(

(

F

F

a

a

c

c

t

t

o

o

r

r

y

y

 

 

R

R

e

e

s

s

e

e

t

t

)

)

 

 

To remove the Keypad from current ZigBee network, the Keypad must be put to Factory Reset to complete device removal. 
Factory Reset function will clear the device of its stored setting information and prompt the Keypad to search for new ZigBee 
network.   

Before removing device, make sure the Keypad is within current ZigBee network signal range 

1.  Press and hold the function button for 10 seconds, then release the button to reset Keypad. 
2.  Upon reset, the Keypad will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove 

itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network 
automatically.   

 

Installation 

l

l

 

 

M

M

o

o

u

u

n

n

t

t

i

i

n

n

g

g

 

 

t

t

h

h

e

e

 

 

R

R

e

e

m

m

o

o

t

t

e

e

 

 

K

K

e

e

y

y

p

p

a

a

d

d

 

 

To mount the remote keypad: 

1.  Remove the front cover by loosening the cover fixing screw using a Philips screwdriver. 
2.  Using the 2 mounting holes of the base as a template, mark off the positions in the most appropriate place. 
3.  Insert the wall plugs if fixing into plaster or brick surface. 
4.  Screw the base onto the wall plugs using a Philips screwdriver. 
5.  Replace the front cover and tighten the cover fixing screw using a Philips screwdriver. 

l

l

 

 

U

U

s

s

i

i

n

n

g

g

 

 

R

R

e

e

m

m

o

o

t

t

e

e

 

 

k

k

e

e

y

y

p

p

a

a

d

d

 

 

w

w

i

i

t

t

h

h

 

 

Z

Z

i

i

g

g

B

B

e

e

e

e

 

 

R

R

o

o

u

u

t

t

e

e

r

r

 

 

IMPORTANT NOTE 

If the Remote keypad installation location is away from your system control panel and requires ZigBee routers to improve 
signal strength. 

DO NOT 

use a ZigBee Router without backup battery. A ZigBee router without battery will be powered down 

during  AC  power  failure  and  the  Remote  keypad  connected  to  the  router  will  lose  connection  with  ZigBee  network.  You 
should plan your Remote keypad installation location using only ZigBee router with backup battery. 