Self-adhesive Mounting
1) The mounting corner should be clean, dry, and smooth. Clean the mounting corner with a suitable degreaser if needed.
2) Two double-sided adhesive pads are attached on the triangular bracket before shipment.
3) Remove the protective covering from the double-sided adhesive pads.
4) Attached the triangular bracket onto the desired corner with the two pointing sticks on top facing you.
5) Fit the PIR onto the hooks of the triangular bracket.
Surface Mounting without mounting bracket:
The PIR can also be mounted on a flat surface with fixing screws, plugs, but without the mounting bracket.
The base has knockouts, where the plastic is thinner and can be broken for mounting purpose. Three knockouts are for surface
fixing as shown in the picture.
To mount the PIR without mounting bracket:
1) Remove the bottom fixing screw and cover assembly.
2) Break through the three knockouts on the inside of base
3) Using the holes as a template, drill holes in the surface.
4) Insert the wall plugs if fixing it into plaster or brick.
5) Screw the base into the wall plugs.
6) Screw the cover onto the base.
Surface Mounting
Surface mounting with rotating bracket (optional item, sold separately):
For surface mounting, an optional rotating bracket is provided for users to adjust the range of detection. With the rotating bracket,
the IR-32 can be rotated 80 degrees horizontally and 70 degrees vertically to provide optimal coverage.
The rotating bracket can be mounted on the wall with provides screws.
1) Screw the rotating bracket into the wall.
2) Fit the 3 hooks of the rotating bracket into the 3 holes of the base accordingly.
3) Rotate the bracket for the proper range of detection and tighten the fixing screw.