is installed in the battery compartment with a battery insulator inserted. To activate the battery, simply 
pull out the battery insulator. 

 

The Door Contact / Shock Sensor can detect low battery condition. When the battery voltage is low, a 
low battery signal will be sent to the Control Panel to notify the condition. The LED will light up when the 
Door Contact / Shock Sensor is activated under low battery status. When the battery is exhausted, the 
Door Contact / Shock Sensor will stop all function, the LED will flash every 4 seconds. 

 

When  changing  batteries,  after  removing  the  old  batteries,  press  the  Tamper  Switch  twice  to  fully 
discharge before inserting new batteries. 

 

Tamper Protection 

 

The  Door  Contact  /  Shock  Sensor  is  protected  by  a  tamper  switch  which  is  compressed  against  the 
mounting  surface  when  the  Door  Contact  /  Shock  Sensor  is  mounted.  Whenever  the  Door  Contact  / 
Shock Sensor is removed from mounted surface or cover is opened, the tamper switch will be activated 
and the device will send a tamper open signal to remind the user of the condition.   

 

The tamper open signal will be transmitted with the Door Contact to the Control Panel. The tamper fault 
status will be displayed only in the DC device zone in the Control Panel. 

 

Supervision 

 

When in normal operation, the Door Contact and Shock Sensor  will send a supervision signal to the 
Control Panel separately at random intervals of 15-18 minutes. 

 

If the Control Panel has not received the supervision signal from the Door Contact / Shock Sensor for a 
preset  period  time,  the  Control  Panel  will  indicate  the  particular  Door  Contact  /  Shock  Sensor  is 
experiencing an out-of-signal problem. 

 

Test Mode 

 

Under Normal Mode, press the Test Button to transmit a test signal and learning code to the Control 
Panel. The Door Contact / Shock Sensor will also enter the Test Mode for 3 minutes. 

 

Under Test Mode, the LED will light up whenever the Door Contact / Shock Sensor is activated. 

 

Each additional Test Button press will reset Test Mode time to 3 minutes. 

 

Getting Started 

 

Remove the battery insulator on the Door Contact / Shock Sensor to power on. 

 

Put the Control Panel into Learning Mode (Please refer to panel operation manual) 

 

Press the Test Button on the Door Contact / Shock Sensor. 

 

Refer to your Control Panel operation manual to complete the learn-in process. 

 

When  learnt  into  the  Control  Panel,  the  DCSV-29  will  be  recognized  as  2  separate  devices  (Door 
Contact & Shock Sensor) and will occupy 2 zones in the Panel. 

 

Set the Material & Sensitivity Level: 
1.  Press the Test Button on DCSV-29 for more than 3 seconds. The LED will turn on, indicating that the 

device  is  now  under  programming  mode.  (If  no  action  within  a  10-second  timeout,  DCSV-29  will 
automatically exit programming mode and return to Test Mode.) 

2.  Select the material and sensitivity level from the Control Panel webpage (Sensor Setting page). 

 