Acoustic Glass Break Detector (ACGS-23ZW) 

The Glass Break Detector detects the high frequency sound emitted by glass breakage and transmits signal 
to notify the alarm system control panel when it is triggered.     
The Glass Break Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network 
and allows access to the “S2 Unauthenticated” class. 
Z-Wave is a wireless communication protocol that uses a low-power RF radio. By taking advantage of the 
Z-Wave mesh network, commands can be transmitted to their destination via intermediary “listening” Z-Wave 
products. 

Parts Identification   

 

1.  Green LED Indicator (Inside) 

Flashes for 1 second: When Detector is powered on. 
Slow Flashes: When the Detector is under Test Mode after Function Button pressed. 
Quick Flash: When Detector is activated under Test mode. 
Flashes once every 4 seconds: Battery is exhausted.

 

2.  Red Indicator (Inside) 

Flashes for 1 second: When Detector is powered on. 

3.    Microphone 
4.    Dip Switch 
5.    Battery Compartment 
6.    Function Button 

-Press the button 3 times within 1 second to send a learn code. 
-Press the button to send wakeup notification report. 
-Press and hold the button for 10 seconds to perform factory reset. 

7.    Tamper Switch 

-The  tamper  switch  is  compressed  against  the  back  cover  and  protects  the  Detector  from  cover 
opening or removal from mounted location 

8.    Breakaway Area 

The Breakaway Area has 2 knockouts where plastic is thinner for screw mounting. When the Detector 
is forcibly removed from mounting location, the Break Away area will detach and allow tamper switch 
to be activated. 

 

Features 

 

Battery  

The Glass Break Detector uses a 3V CR123A Lithium battery. 
The Glass Break Detector will report its battery percentage to the Control Panel respectively at 100% 
(0x64),  75%  (0x4B),  50%  (0x32)  and  25%  (0x19).  If  the  battery  voltage  is  low  (25%),  a  Low  Battery 
signal will be sent to the Control Panel to notify the user. When battery level is dead (cut off), the sensor 
will send 0xFF to the Gateway/Control Panel. 
The Glass Break Detector can detect low battery voltage. When low battery voltage is detected, a low 
battery signal will be sent to the Control Panel along with regular signal transmissions for the Control 
Panel to display the status accordingly. 