Tranquility Aluminum Tube Cased Coil (TAC) 

R e v. :   A u g u s t   2 1 ,   2 0 1 8

8

G e o t h e r m a l   H e a t i n g   a n d   C o o l i n g

Installation

The Tranquility Cased Coils are designed for upflow, horizon-

tal, and downflow applications. The coils have a dry nitrogen 

holding charge and are equipped with brazing stub refriger-

ant connections for easy installation.

The installer should read the installation manual supplied 

with the compressor section for refrigerant line set sizing, 

connection procedure, and other important information per-

taining to the system installation.

The installer should:

1. Make sure that the air delivery of the furnace is adequate 

enough to handle the recommended CFM and allow for 

pressure drop across the air coil, filter, and duct work.

2. Where precise forming of refrigerant lines is required, a 

copper tubing bender is recommended for small diameter 

tubing. One should avoid sharp bends and contact of the 

refrigerant lines with metal surfaces.

3. Refrigerant lines should be protected where they pass 

through the raw edges of holes.

4. Coil must be level or slightly pitched toward drain for 

proper condensate drainage.

5. Seal the openings into the cabinet to reduce risk of con-

densate blow off from the coil.

The installer should:

1. Disconnect all electrical power to the furnace.

2. For the install of an cased coil, it might be necessary to 

fabricate a plate to adapt the coil’s cabinet to the furnace 

or air handler air discharge opening.

3. Install the cabinet and level or slightly pitch it as needed to 

allow proper condensate drainage.

4. Seal the enclosure as required minimizing air leakage.

5. Connect the refrigerant lines as outlined in the Refrigerant 

Lines section.

Cased Coil Installation

� 

WARNING! 

WARNING!  

Electric furnaces may be connected to

more than one supply circuit.

Содержание Tranquility TAC026BM17S

Страница 1: ...tenance Instructions 97B0100N01 Rev August 21 2018 Tranquility Aluminum Tube Cased Coil TAC Table of Contents Model Nomenclature 3 General Information 4 Safety Inspection 5 Specifications 6 Dimensions...

Страница 2: ...This page was intentionally left blank...

Страница 3: ...ture AC T B 026 2 3 1 4 5 6 7 T TRANQUILITY HFC 410A MODEL TYPE AC CASED COIL CONFIGURATION 026 NOMINAL CAPACITY 038 049 REVISION LEVEL 064 M 8 COIL OPTIONS M MULTI POSITION CASED COIL S 11 FUTURE USE...

Страница 4: ...r to file all necessary claims with the carrier Notify your equipment supplier of all damage within fifteen 15 days of shipment Storage Equipment should be stored in its original packaging in a clean...

Страница 5: ...ion which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unsafe practice which if not avoided could result in minor or moderate injury...

Страница 6: ...0 42 17 5 44 5 0 120 0 157 0 199 0 246 TAC026BM21S 5 70 0 53 21 53 3 0 113 0 145 0 181 0 222 TAC038BM21S 8 55 0 79 0 062 0 086 0 112 0 140 0 170 0 202 0 236 TAC038BM24S 8 55 0 79 0 062 0 086 0 112 0...

Страница 7: ...ZONTAL PRIMARY DRA N I SUCTION LINE LIQUID LINE SECONDARY DRAIN NOTE FLANGES ARE PROVIDED FOR FIELD INSTALLATION SECONDARY DRAIN 3 4 19 1 mm FPT HORIZONTAL Coil Model Number Connections Cased Coil Dim...

Страница 8: ...d a copper tubing bender is recommended for small diameter tubing One should avoid sharp bends and contact of the refrigerant lines with metal surfaces 3 Refrigerant lines should be protected where th...

Страница 9: ...ce seal the gap between the two units with sheet metal See figure 4 CAUTION CAUTION For horizontal applications the horizontal drain pan must be located under the indoor coil Failure to place the pan...

Страница 10: ...ANT Seal the gap between the two units with appropriate sheet metal parts Figure 3 Installation of coil matched with a furnace two sizes smaller Figure 4 Installation of coil matched with a furnace of...

Страница 11: ...oists wall studs floors or other structural components that could transmit compressor vibration Do not suspend refrigerant tubing from joists with rigid straps Do not attach line set to the wall When...

Страница 12: ...failure of the aluminum tube Installation Evacuation LEAK TESTING The refrigeration line set must be pressurized and checked for leaks before evacuating and charging the unit To pressurize the line se...

Страница 13: ...hat a problem exists if water should begin running from the auxiliary drain line Plug the unused drain connection with the plugs provided in the parts bag using a thin layer of Teflon paste silicone o...

Страница 14: ...sulting in property damage personal injury or death For continuing high performance and to minimize possible equipment failure it is essential that annual maintenance be performed on this equipment Co...

Страница 15: ...r labels or rating labels have been removed or defaced 5 Products on which payment to CM or to the owner s seller or installing contractor is in default 6 Products which have not been installed and ma...

Страница 16: ...cific information on the current design and specifications Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but...

Отзывы: