7
HERMETIC COMPRESSORS
Performance Data - Low Temperature (R-404A/507)
* = T for Outdoor, N for Indoor, S for Beacon II™
R-404A/507
Model
Compressor
Capacity BTUH @ 90°F Ambient Suction Temperature
0°F
-5°F
-10°F
-20°F
-25°F
-30°F
CH*011L6
CF04K6E
7,030
6,240
5,370
3,850
3,330
2,630
CH*014L6
CF06K6E
10,500
9,380
7,830
6,090
4,890
4,080
CH*019L6
CF06K6E
12,100
10,180
8,910
6,580
5,530
4,570
CH*025L6
CF09K6E
15,550
14,500
12,700
9,000
7,560
6,230
CH*031L6
CF12K6E
18,840
17,800
15,140
11,540
9,790
8,070
R-404A/507
Model
Compressor
Capacity BTUH @ 95°F Ambient Suction Temperature
0°F
-5°F
-10°F
-20°F
-25°F
-30°F
CH*011L6
CF04K6E
6,840
5,750
4,920
3,650
3,020
2,360
CH*014L6
CF06K6E
9,900
8,840
7,750
5,670
4,710
3,680
CH*019L6
CF06K6E
11,400
10,100
8,750
6,040
5,030
4,150
CH*025L6
CF09K6E
15,400
13,700
12,000
8,300
6,950
5,750
CH*031L6
CF12K6E
17,690
16,800
14,360
10,910
9,170
7,470
R-404A/507
Model
Compressor
Capacity BTUH @ 100°F Ambient Suction Temperature
0°F
-5°F
-10°F
-20°F
-25°F
-30°F
CH*011L6
CF04K6E
6,310
5,170
4,460
3,300
2,660
2,070
CH*014L6
CF06K6E
9,310
8,280
7,280
5,280
4,350
3,510
CH*019L6
CF06K6E
10,700
9,430
8,170
5,810
4,570
3,700
CH*025L6
CF09K6E
14,500
12,800
11,200
8,130
6,410
5,220
CH*031L6
CF12K6E
17,600
15,090
13,410
10,700
9,040
7,320
R-404A/507
Model
Compressor
Capacity BTUH @ 110°F Ambient Suction Temperature
0°F
-5°F
-10°F
-20°F
-25°F
-30°F
CH*011L6
CF04K6E
5,240
4,450
3,620
2,630
2,100
–
CH*014L6
CF06K6E
8,310
7,340
6,420
4,580
3,730
2,990
CH*019L6
CF06K6E
9,330
8,170
7,040
4,920
3,980
3,090
CH*025L6
CF09K6E
12,700
11,400
9,900
7,030
5,760
4,590
CH*031L6
CF12K6E
15,700
14,000
12,400
9,250
7,690
6,100