IMPORTANT REMINDERS 

 

Please read the manual carefully before operating the cooler. 
 

A)

 

Operating conditions: 
 

1- Temperature: 18C to 45C; Water Temperature: < 45C. 
2- Power supply must not exceed the required voltage (+/-) 5% 
3- Air supply must be largely free of dust or extra cleaning is required. 
 
B) Protect the power cable from vehicle or foot traffic. Connection to incorrect electric voltage, 
or faulty installation, will cause danger of electric shock. 
 
C) If the product malfunctions at startup, please disconnect from electric power immediately 
and refer to dealer for service. 
 
D) Other tips for cooler use: 
 
1- Keep doors and windows open to allow fresh air to enter, and treated air to exit, when cooler 
is operating. 
2- Flashing red light on the control panel means water level in reservoir is low. 
3- Rinse the reservoir with fresh water and clean prior to use after a period where the cooler 
has not been in operation. 
4- Take care when moving the cooler, especially when it is full of water. Pushing too hard will 
cause the cooler to overbalance and tip over, which may cause injury and will damage the 
cooler. 
5-To prevent buildup of algae and other biological organisms in the reservoir, regularly add 
chlorine/bromine tablets manufacturer recommendation for evaporative cooler reservoirs. 
 

 
 

 
 
 
 
 
 
 
 

 
 

-03- 

Содержание CM-18000

Страница 1: ...EVAPORATIVE AIR COOLER CM 18000 www climateplus ae...

Страница 2: ...used supplied as standard a float valve keeps the reservoir full continuously If filled manually the big 60 Litre capacity reservoir ensures hours of uninterrupted operation There is a digital level i...

Страница 3: ...Dimension L W H mm 1120x700x1650 Weight kg 63 Effective Cooling Area m2 100 150 TECHNICAL FEATURE New evaporative cooling pad energy levels fan speed low medium high saving and environmentally friend...

Страница 4: ...power immediately and refer to dealer for service D Other tips for cooler use 1 Keep doors and windows open to allow fresh air to enter and treated air to exit when cooler is operating 2 Flashing red...

Страница 5: ...EVAPORATIVE AIR COOLER CM 18000 www climateplus ae KEY COMPONENTS 04...

Страница 6: ...When COOL is pressed again the water evaporation feature is turned off with only the fan operating SPEED Pressing SPEED will select low medium or high fan speed SWING This activates deactivates swing...

Страница 7: ...EVAPORATIVE AIR COOLER CM 18000 www climateplus ae CONTROL PANNEL REMOTE CONTROLLER 06...

Страница 8: ...nner side is towards motor Never use any liquid detergent Never use pressurized water as it may cause damage to the pad 3 Unscrew the drainage lid to let dirty water flow out then clean the water tank...

Страница 9: ...inner side is towards motor Never use any liquid detergent Never use pressurized water as it may cause damage to the pad 3 Unscrew the drainage lid to let dirty water flow out then clean the water ta...

Страница 10: ...is nothing preventing free rotation of the fan Clean the cooling pad and dust filter Change the fan Change the main control board Motor does not respond to control panel Main control board failure Pan...

Отзывы: