background image

Timer op tions

The system’s built-in electronic timer can be optionally wired to provide one of several different  functions. Timer duration settings can be made by your

installing Clifford Dealer or by you via the CliffNet Wizard. Ask your Authorized Clifford Dealer for further details:

  Re mote con trolled timed head light activation option  

The timer can be wired to provide remote controlled headlight activation for any duration you wish  between 1 second and 4 minutes, allowing you to
remotely light your way to and from the vehicle by pressing the 

 button on your remote control.

  Win dow AutoClose op tion   

The timer can automatically close the windows upon remote arming on vehicles with an “all-close” feature that raises them if the key is held in the driver's

door (a common feature on several European vehicle models). 

NOTE: Although this timer circuit could be wired to control power windows on non-European cars that do not have
this key-in-the-door “all-close” feature, Clifford Electronics strongly recommends against this. If so wired, the timer
would force the window motors to “shut” the windows even if they were already closed. This places excessive strain
on the vehicle’s window motors, causing overheating, premature failure and even the possibility of  fire. As such, if
you cannot close the windows of your vehicle by turning and holding the key in the driver’s door, do not permit the
system’s timer circuit to be wired to automatically close the windows.

If your car does not have an all-close feature, one or more SmartWindows 4 accessories are needed.  One SmartWindows 4 module can control two power

windows. In addition to automatically closing the power windows every time you arm, SmartWindows 4  also allows you to remotely roll down the

windows after disarming and to remotely vent them open slightly for ventilation on hot days. Inside the car, SmartWindows 4 also provides one-touch full 

open, one-touch full close and one-touch stop to each of your factory window control switches.

Win dow AutoClose In stant By pass  

If you have the timer-based window closure option noted above, you may choose to arm 

without

 automatically closing the windows. This is handy on hot

days by allowing you to leave one or more windows slightly open while the system remains armed. To  do so, simply turn the ignition switch to “ON” and

then “OFF” rapidly. You will hear a chirp confirmation (this action also activates 

Instant AutoArming bypass

 prevously noted). When you then exit and

arm, the system will 

not

 close the windows. Normal autoclose operation is restored the next time you arm.

  Turbo timer op tion  

Vehicles that have turbocharged engines often require a cool-down period of one to several minutes  after driving, particularly high-rev driving. Until now, 

drivers of such vehicles had two choices: sit in the car after parking and wait several minutes to  turn off the engine, or have an expensive turbo timer

accessory added that would often interfere with car alarm operation. But with the addition of an optional relay, your system’s timer output can save you

money and make turbo cool-down easy and convenient. If you have this option installed, just press the assigned button or button combination(your

Clifford installer will have told you which he has assigned to this function) on the remote control before shutting off the engine. Then remove your car
key (the engine will continue running), exit, and press the 

 button to arm the system and lock the doors. While the system is armed, your

IntelliGuard 6000 will continue to idle the engine for any duration you choose up to 4 minutes. To  ensure against any possibility of false alarms, the

system will keep the sensors offline while the engine is idling, then automatically bring them back online right after the engine is shut down.

Smart Au toTest ing™

Each time you remotely arm the system, it tests all triggers and sensors. If the 

hood or trunk

 is open, the system will 

immediately

 sound 

4 chirps

 and 

4

indicator light flashes

 instead of the usual 2 and 2. If a

 door

 is ajar, you’ll receive 2 chirps and 2 flashes, then, 

5 seconds later

, there will be 

4 chirps

 and 

4

flashes

. If a 

sensor

 is malfunctioning, you will receive the usual 2 chirps and 2 flashes, then, 

10 seconds later

, there will be 

4 chirps

 and 

4 flashes

.

NOTE: Since this is a warn ing in di ca tion, you will hear the 4 chirps even if you use the chirp  mut ing fea ture.

n

Specific malfunction identification:

The system can also indicate the 

specific

 trigger or sensor that is malfunctioning. If you get the

4-chirp/4-flash signal upon arming, perform the following to identify the malfunctioning trigger or sensor:

1. Remotely disarm, then turn on the ignition. The LED status indicator inside your vehicle will be flashing, pause, then repeat.  

2. Count the number of flashes in one cycle between pauses (for your convenience, the flash cycle repeats a total of 5 times) and refer to the chart below:

LED flashes

Mean ing

1 flash

Activation of Glass Tampering Sensor

2 flashes

Activation of Piezo Sensor

4 flashes*

Door open/ajar

5 flashes

Trunk/hood open/ajar (trunk only if you have the IntelliStart 4 option)

6 flashes

Hood open/ajar (only if you have the IntelliStart 4 option)

7 flashes

Ignition switch was turned on while the system was armed

8 flashes

Three or more incorrect valet codes were entered

10 flashes

Power tampering or the vehicle battery is very low

* If your ve hi cle has a factory- installed fea ture that turns off or dims the in te rior cour tesy lights sev eral sec onds af ter you exit the ve hi cle, the sys tem can not pro vide this in di ca tion.

7

Содержание IntelliGuard 6000

Страница 1: ......

Страница 2: ...l of your system via your Windows PC n For smart accessory interfacing FACT anti false alarm circuitry Passive AutoArming if you forget to arm with the remote control n Lock upon AutoArming self locki...

Страница 3: ...hree seconds continually press button The parking lights will flash repeatedly and the siren will blare for 30 seconds American model or until you press the button again European model If the ignition...

Страница 4: ...arm or use the engine restart feature below Optional Wireless Immobilizer Clifford s optional Wireless Immobilizer interrupts a third point in the vehicle such as the fuel pump This Clifford innovatio...

Страница 5: ...valet code feature is in column 2 row 7 2 Enter program mode by turning on the ignition entering your current code then pressing and holding the button of the PlainView 2 switch for 3 seconds until y...

Страница 6: ...light flashes will continue to provide visual confirmation of remote controlled system arming and disarming See User selectable features n Selectable siren duration non European models only You may c...

Страница 7: ...one to several minutes after driving particularly high rev driving Until now drivers of such vehicles had two choices sit in the car after parking and wait several minutes to turn off the engine or ha...

Страница 8: ...ashes between pauses and refer to the chart above With the optional CliffNet Wizard you ll see this chronological report right on screen SmartPowerUp 2 If power is removed SmartPowerUp 2 ensures the s...

Страница 9: ...e setting 7 You may now select another feature or exit program mode a To select another feature in that same column repeat step 5 within the next 5 seconds after 5 seconds 3 chirps mean you are back t...

Страница 10: ...the other car s remote to arm and disarm this system select column 4 row 1 then press the button of the other car s remote you ll hear one chirp Immediately press the button again you will hear a 2 ch...

Отзывы: