background image

© 2004 Directed Electronics, Inc. Vista, CA  N909600  08-04

installation guide

Содержание Concept 450

Страница 1: ...2004 Directed Electronics Inc Vista CA N909600 08 04 installation guide...

Страница 2: ...uitry NPC Revenger Silent Mode Soft Chirp Stinger Valet Vehicle Recovery System VRS and Warn Away are all Trademarks or Registered Trademarks of Directed Electronics Inc Vista California I IM MP PO OR...

Страница 3: ...mounting the receiver antenna 19 arming disarming diagnostics 20 arming 20 disarming 20 system status chirps 21 remote siren silencing 21 multiple event total recall 21 system features programming 22...

Страница 4: ...a standard configuration transmitter standard configuration Button The arming disarming and panic function are controlled by this button Button The trunk release or accessory output A is controlled b...

Страница 5: ...vision Output 30 WHITE Light Flash Output WHITE Light Flash Output WHITE RED Light Flash Input BROWN Speaker Output 2 RED 12V Constant GREEN Door Trigger Input Zone 4 VIOLET Door Trigger Input Zone 4...

Страница 6: ...the BLACK wire to a clean paint free sheet metal location driver s kick panel using a factory bolt that does NOT have any vehicle component grounds attached to it A screw should only be used in conjun...

Страница 7: ...n Zone 5 It can also be used with Directed single stage sensors h1 8 violet door trigger input zone 4 Connect the violet wire to a wire that shows 12V when any door is opened This wire will report Zon...

Страница 8: ...light flash polarity before connecting H1 12 or damage to the vehicle lighting system could occur h1 15 black white dome light supervision output Connect the H1 15 BLACK WHITE wire to the vehicle dom...

Страница 9: ...on input 87 This wire determines the output of the BLACK WHITE H1 15 wire on the main 18 pin harness If the vehicle has a negative domelight circuit ground this wire if the vehi cle has a positive dom...

Страница 10: ...possibility of failure due to power loss that could potentially strand the user The level of security can be set by leaving in or removing the jumper located next to the immobilizer wires exiting the...

Страница 11: ...ave ground on the 18 pin harness door lock harness wire connection guide ___ ___ ___ I IM MP PO OR RT TA AN NT T The door lock outputs are low current and should not be attached direct ly to any high...

Страница 12: ...e sure that it is not a Type C direct wire system Cut the wire that pulses 12 volt on lock and then operate the switch to unlock z If all doors unlock the vehicle uses type A system z If you lose all...

Страница 13: ...se locking are high current so a 451M or 2 relays need to be used The switch will have three wires on it and one wire will test ground all the time One wire will pulse negative when the switch locks t...

Страница 14: ...res The switch that lost all operation is the master switch If one switch works in both directions and the other switch works in only one direction you have a Type A system If both switches still oper...

Страница 15: ...ed Vehicles without factory power door locks require the installation of one actuator per door This requires mounting the door lock actua tor inside the door Other vehicles may only require one actuat...

Страница 16: ...from the passenger key cylinder If all the doors lock the vehicle s door lock system can be controlled with just two relays optional The control wire can be found in either kick panel and will show 1...

Страница 17: ...cutting the wire to lock the door In some vehicles these functions are reversed Type F door locks are found in late model Nissan Sentras some Nissan 240SX and Nissan 300ZX 1992 up They are also found...

Страница 18: ...relays or a DEI 451M must be used Single Resistor Type If one resistor is used in the door lock switch key cylinder the wire will pulse 12 volt in one direction and less than 12 volt when operated in...

Страница 19: ...relays or a DEI 451M must be used Single Resistor Type If one resistor is used in the door lock switch key cylinder the wire will pulse ground in one direction and resistance to ground when operated i...

Страница 20: ...the back of a panel drill a mounting hole using a 17 64 inch drill bit Be sure to check for clearance prior to drilling the mounting hole plain view valet The Valet Program switch should be accessible...

Страница 21: ...ition to locate the receiver antenna is centered high on either the front or rear windshield For optimal range the antenna should be mounted vertically It can be mounted horizontally in relation to th...

Страница 22: ...em is armed are reported by an addition al set of status chirps called Malfunction AutoBypass The specific zone bypassed is then reported by the LED For more zone information refer to Table of Zones s...

Страница 23: ...ill holding arm and disarm the system then release the button 3 The LED will start to blink to indicate the most recent trigger and proceed down to the eighth trigger If fewer than eight triggers are...

Страница 24: ...electable Features grid allows the installer to change input output functions of the system to integrate with the vehi cle s specific characteristics cliffnet wizard pro installation software programm...

Страница 25: ...Feature select Press the same number of times as the desired feature The siren will chirp with each press The feature can now be changed using the remote control 6 Feature change Press the arm disarm...

Страница 26: ...later chirps off on quiet z Off Chirps will not sound when arming disarming the system z On Chirps will sound when arming disarming the system z Quiet Chirps will sound when arming disarming the syst...

Страница 27: ...0 90 z The system will sound the alarm for the programmed duration 30 60 90 seconds during an alarm trigger or when the system is put into panic mode second unlock off on z Off Second unlock output is...

Страница 28: ...on z Off The panic feature is not available z On The panic feature is available auto start setting off battery only temp only battery and temp z Off The vehicle will not autostart z This feature is o...

Страница 29: ...eature will make the system enter exit valet mode remote start z This feature is only available with IntelliStart connected z The transmitter channel programmed into this feature will activate or shut...

Страница 30: ...nnected Only with optional SmartWindows connected Remote adjustable sensor port The 3 pin proximity shock port can be used for either the proximity sensor or the remote adjustable magnetic res onance...

Страница 31: ...n Smart auto testing will ignore the domelight until it goes off accessory output b auto activation N NO OT TE E The accessory output will not auto activate if programmed to latched setting z Off z Ar...

Страница 32: ...en the ignition is turned on one time valet off on z Off Does not allow one time valet mode feature z On Allows one time valet mode feature accessory output a timer duration z Start Timer Press the ar...

Страница 33: ...the wait to start input wires N NO OT TE E RPM must be reprogrammed after changing this feature smart windows program z This feature applies only if SmartWindows is installed z Enter this feature and...

Страница 34: ...figuration an arm dis arm channel must first be programmed before programming the remaining channels Note 3 Selecting siren sounds After entering this feature press the arm disarm button The siren wil...

Страница 35: ...4 Wait for two siren chirps after a five second pause or five seconds after the last digit has been entered if using less than four digit code number 5 Turn off the ignition the siren will chirp three...

Страница 36: ...imer duration setting or for maximum time do not press the arm disarm button N NO OT TE E The timer max setting is 255 seconds fact II false alarm control technology FACT II will bypass an input zone...

Страница 37: ...he sensor zones will reset when disarmed mux sensors audio sensor The 506T Audio Sensor is a low current device that provides an added level of protec tion to an existing security system by detecting...

Страница 38: ...rn the sensor screw clockwise for higher sensitivity or counter clockwise for less sensitivity auto immobilization feature Immobilizer circuits automatically activate after 30 seconds N NO OT TE E H1...

Страница 39: ...off ON Valet mode will be exited every time the ignition is turned on OFF Valet mode will only be exited by using the valet switch or the remote control second unlock feature OFF H2 12 Blue white wir...

Страница 40: ...ng door input has been used The system will not passively arm until it is remotely armed and then disarmed z Are the door inputs connected Is a BLUE wire connected to the door trigger wire in the vehi...

Страница 41: ...er Input Zone 4 BLUE Trunk Trigger Input Zone 5 WHITE BLUE Accessory B Output 200mA GREEN WHITE Normally Closed Zone 6 WHITE Light Flash Output WHITE Light Flash Output WHITE RED Light Flash Input RED...

Страница 42: ...www directed com 40 BLACK WHITE Domelight Supervision Input 87 EMPTY YELLOW WHITE Horn Honk Output 200mA EMPTY EMPTY 6 Pin Secondary Harness BLUE WHITE Second Unlock Output 200mA...

Страница 43: ...M TM Immobilizer Harness Immobilizer Jumper RF Port Mux Sensor Port Shock or Proximity Sensor Port CliffNet Wizard Port Smart Self Powered Siren Power 6 Pin Harness 18 Pin Harness LED Port PlainView 2...

Страница 44: ......

Страница 45: ...________________________________________ ________________________________________ ________________________________________ ________________________________________ ___________________________________...