21
© 2014 Directed. All rights reserved.
Full Silent Arm Protection
Sensor Warn-away, Sensor Full Trigger and Point of Entry activations
will only send messages to the Responder LE remote control, with park-
ing light flash and siren outputs defeated.
Sensor Warn-away
When the system sensors detect a Warn-away trigger the siren chirps
and parking lights flash for three seconds. Warn-away messages are
sent to the Responder LE remote control.
Full Trigger
An alarm Full Trigger will sound the siren and flash the parking lights
for 30 seconds while sending a Full Trigger message to the Responder
LE remote control. The confirmation LED’s flash and siren tones play
for 30 seconds.
Emergency Override
The following procedure disarms the system when a programmed re-
mote is not available. Number of presses__________
1.
Turn
the ignition On.
2.
Press
and release the control button on the Control Center
the correct number of times (the default is one press).
3. After a few seconds the siren output ceases and the system
is disarmed.
Note
As a precaution, if programmed for Passive Arming or Auto
re-arming the system should be placed into Valet Mode until
a remote is available .