background image

Note of location of 

the inner           for the 

future pilot hole

Lamination Instructions Continued:

Cut out the panels:

9

Sand edges

Clear tube holes

Prepare housing:

10

Finish sanding exit 

holes by hand until extra smooth

1. Trim tube ends 

     to edge of housing

2. Clear all debris

Grind 

fl

ush with top of reel housing.

Take care to not damage reel housing.

Use small end of blade for round corners

Scalloped blade

Drill pilot hole to access tab for reel removal:

11

Locate inner          for 

pilot hole.

Drill through 

lamination at an 

angle creating a 

tunnel to access the 

pilot hole & release 

tab (2mm drill bit).

Test and clear hole 

before installing 

dial.

Fabricate and install pads:

12

Pad thickness, material and shape 

are used to re

fi

ne pressure and 

fi

t.

Pad Material:

 Pads should be 

dense enough to create pressure 

and not compress under tension.

Pad Thickness:

 Average 3/16” 

(4.75mm) Push shore: 35

Slight convex 

shape allows 

for better 

application of 

pressure.

Convex pad

Skive edges

Panel

INCORRECT - Pad too thin when panel is 

fl

ush with socket

CORRECT - Pad is the correct thickness when panel sits above socket when 

fi

t is snug to patient

Good Closure Force

Weak Closure Force

5-10mm

Frame

Critical distance

Pad

Panel

Frame

Pad

Panel

Содержание RevoFit2

Страница 1: ...niquement par un professionnel certifié formé au système RevoFit Le filament sera porté inspecté et remplacé régulièrement Beratend Nicht bei Patienten mit Neuropathie Neuromen oder anderen Nervenproblemen anwenden Fertigung nur durch einen zertifizierten Fachmann der im RevoFit System geschult wurde Filament wird regelmäßig getragen kontrolliert und ersetzt Consultivo No lo use en pacientes con n...

Страница 2: ......

Страница 3: ...or Above Knee 2 System with Medial Lateral Panels Adjustable Strap Recommended Suspension System RevoLock Lanyard Kit PN 3000 220 05 Patient Replacement Lace Pack Additional Kit Required Accedents happen WE GET IT For any warranty or product failure please do not return to distributor simply contact CLICK MEDICAL DIRECTLY AT Help ClickMedical co Help Line 970 670 7012 WARRANTY ...

Страница 4: ...nt Determine lace routing For Inline Routing Use port II and III For Remote Routing Use port I and II Inline mounted on panel Remote mounted on socket frame Inline mounted on socket frame Determine location of reel Glue on RevoFit Components Laminate Cut Out Windows 4 Install Shape Pads Lace Socket Install Reel Tune Pads ...

Страница 5: ...ith the spacing rule b Ensure tubing crosses panels perpendicularly c Don t turn tubing until 1cm past any panel edge Do not kink tubing 1 2 1 4 1 4 1 4 1 4 Laminate again 7 Glue on tubing 5 Trim one tube pack with clay insert into bayonet c Insert Tube Make sure tubing is inserted 2cm into silicone 6 b Pack Clay Cut off tabs for lamination a Cut at an angle so tube pierces into the silicone easil...

Страница 6: ...on at an angle creating a tunnel to access the pilot hole release tab 2mm drill bit Test and clear hole before installing dial Fabricate and install pads 12 Pad thickness material and shape are used to refine pressure and fit Pad Material Pads should be dense enough to create pressure and not compress under tension Pad Thickness Average 3 16 4 75mm Push shore 35 Slight convex shape allows for bett...

Страница 7: ...eedle nose vise grips Rotate clockwise to remove Tab location Finished Push towards center of reel 1 4 turn Turn the housing not the dial itself Pull dial to open Inline Depending on the location either at 4 o clock or 11o clock Always at 8 30 Remote Fit patient Tune in fit by refining pad shape if necessary Provide IFU s and replacement lace pack to patient a Open dial b Use tool to press inward ...

Страница 8: ... PEL LLC ph 800 321 1264 www pelservice com Distributed by ...

Отзывы: