background image

(MDD) - 93/42/EEC

harmonized & notified body 

Click Medical, LLC

1205 Hilltop Parkway 

Warehouse 101

Steamboat Springs, CO, USA

(970) 670-7012

RevoFit2

™ 

Lamination Kit

PK2000-320-05

REF    PK001

Advisory: 

Do not use on patients with neuropathy, neuromas, or other nerve issues. 

Fabrication only by a certi

fi

ed professional, trained in the RevoFit™ system. 

Filament will wear, inspect and replace regularly. 

Consultatif:

Ne pas utiliser chez les patients atteints de neuropathie, de névrome ou d'autres problèmes 

nerveux. Fabrication uniquement par un professionnel certi

fi

é, formé au système RevoFit. Le 

fi

lament sera porté, inspecté et remplacé régulièrement.

Beratend:

Nicht bei Patienten mit Neuropathie, Neuromen oder anderen Nervenproblemen anwenden. 

Fertigung nur durch einen zerti

fi

zierten Fachmann, der im RevoFit System geschult wurde. 

Filament wird regelmäßig getragen, kontrolliert und ersetzt.

Consultivo: 

No lo use en pacientes con neuropatía, neuromas u otros problemas nerviosos. 

Fabricación solo por un profesional certi

fi

cado, entrenado en el sistema RevoFit. 

El 

fi

lamento se desgastará, inspeccionará y reemplazará regularmente.

US PATENT# 8443501

WE ARE HERE TO HELP! 

Tech Support: 970 670 7012

ClickMedical.co/RevoSupport

[email protected]

Содержание RevoFit2

Страница 1: ...niquement par un professionnel certifié formé au système RevoFit Le filament sera porté inspecté et remplacé régulièrement Beratend Nicht bei Patienten mit Neuropathie Neuromen oder anderen Nervenproblemen anwenden Fertigung nur durch einen zertifizierten Fachmann der im RevoFit System geschult wurde Filament wird regelmäßig getragen kontrolliert und ersetzt Consultivo No lo use en pacientes con n...

Страница 2: ......

Страница 3: ...or Above Knee 2 System with Medial Lateral Panels Adjustable Strap Recommended Suspension System RevoLock Lanyard Kit PN 3000 220 05 Patient Replacement Lace Pack Additional Kit Required Accedents happen WE GET IT For any warranty or product failure please do not return to distributor simply contact CLICK MEDICAL DIRECTLY AT Help ClickMedical co Help Line 970 670 7012 WARRANTY ...

Страница 4: ...nt Determine lace routing For Inline Routing Use port II and III For Remote Routing Use port I and II Inline mounted on panel Remote mounted on socket frame Inline mounted on socket frame Determine location of reel Glue on RevoFit Components Laminate Cut Out Windows 4 Install Shape Pads Lace Socket Install Reel Tune Pads ...

Страница 5: ...ith the spacing rule b Ensure tubing crosses panels perpendicularly c Don t turn tubing until 1cm past any panel edge Do not kink tubing 1 2 1 4 1 4 1 4 1 4 Laminate again 7 Glue on tubing 5 Trim one tube pack with clay insert into bayonet c Insert Tube Make sure tubing is inserted 2cm into silicone 6 b Pack Clay Cut off tabs for lamination a Cut at an angle so tube pierces into the silicone easil...

Страница 6: ...on at an angle creating a tunnel to access the pilot hole release tab 2mm drill bit Test and clear hole before installing dial Fabricate and install pads 12 Pad thickness material and shape are used to refine pressure and fit Pad Material Pads should be dense enough to create pressure and not compress under tension Pad Thickness Average 3 16 4 75mm Push shore 35 Slight convex shape allows for bett...

Страница 7: ...eedle nose vise grips Rotate clockwise to remove Tab location Finished Push towards center of reel 1 4 turn Turn the housing not the dial itself Pull dial to open Inline Depending on the location either at 4 o clock or 11o clock Always at 8 30 Remote Fit patient Tune in fit by refining pad shape if necessary Provide IFU s and replacement lace pack to patient a Open dial b Use tool to press inward ...

Страница 8: ... PEL LLC ph 800 321 1264 www pelservice com Distributed by ...

Отзывы: