Power cables
Power input and throughput cables must be rated 16A minimum, have three conductors 1.5 mm² (16 AWG) minimum conductor size and
an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or equivalent) and heat- resistant to 90°C minimum. In the
EU the cable must be HAR approved or equivalent.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 16A minimum. Follow the plug
manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some possible pin identification schemes; if pins are
not clearly identified.
Data link
A DMX 512 data link is required in order to control a fixture via DMX. The fixture has 5-pin XLR connectors for DMX data input and output.
The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+) Pins 4 and 5 in the 5-pin XLR connectors are not in use.
Tips for reliable data transmission
To connect the fixture to data:
1.
Connect
the DMX data output from the controller to the 5-pin XLR connector of the nearest fixture.
2.
Connect
the DMX output of the first fixture to the DMX input of the next fixture and continue connecting fixtures.
Relaying power to other devices
Warning! Do not connect more than five fixtures in total in one interconnected chain. Power can be relayed to another device via the
PowerCON TRUE 1 ® throughput socket.
If you daisy chain the fixtures in a chain so that they all draw AC mains power via the first fixture, certain points must be respected:
A
heavy duty, three-conductor, 16 AWG or 1.5 mm2 cable with SJT or equivalent cable jacket must be used to connect the first fixture to
AC mains power. PowerCON
TRUE1 ® connectors must be used to draw AC mains power from the fixtures power throughput socket and
yellow PowerCON TRUE 1 ® connectors must be used to supply power at the fixture’s power input sockets.
Wire Color (EU models)
Wire Color (US models)
Conductor
Symbol
Brown
Black
Live
L
Blue
White
Neutral
N
Yellow/Green
Green
Ground (earth)
or
Table 1: Wire color-coding and power connections
Содержание POSEIDON HYBRID
Страница 1: ...WWW CLF LIGHTING COM V2 0 APRIL 2021 POSEIDON hybrid manual hybrid ...
Страница 3: ...Dimensions in millimeters WWW CLF LIGHTING COM 1 hybrid ...
Страница 6: ...WWW CLF LIGHTING COM 4 Fixture overview ...
Страница 25: ...WWW CLF LIGHTING COM 23 gobo overview ...
Страница 26: ...WWW CLF LIGHTING COM 24 photometrics ...
Страница 27: ...WWW CLF LIGHTING COM 25 circuit connection diagram ...
Страница 30: ...WWW CLF LIGHTING COM CLFLIGHTING poseidon HYBRID ...