background image

V1

.

0

 

JANUARY

 

2017

WWW

.

CLF

-

LIGHTING

.

COM

manual

ARES XS

ARES XS

Содержание ARES XS

Страница 1: ...V1 0 JANUARY 2017 WWW CLF LIGHTING COM manual ARES XS ARES XS ...

Страница 2: ...xture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 W DMX Control 8 Control Mode 9 DOLEUDWLRQ options 10 Auto Show 10 Master Slave 10 Personality 11 Fans 11 Led power 11 Dimmer Speed 11 Key Lock 11 W DMX 11 Calibration 11 Refresh rate 11 LCD brightness 11 DMX Hold 11 Information 11 Software type 11 Usage time 11 Temperature 11 UID 11 Factory reset 11 DMX pro...

Страница 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 381 233 111 336 286 ...

Страница 4: ...tion Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Power input and through out cables must be rated 20A minimum have three conductors 1 5 mm 16 AWG minimum conductor size and an outer cable diameter of 5 15 mm Cables must be hard usage type SJT or equivalent and heat resistant...

Страница 5: ... not use fixture on a dimmer Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 3 meters and above light output is harmless to the naked eye provided that the eye s natural aversion resp...

Страница 6: ... DMX output 3P DMX input optional CLF 13 453 3P DMX output optional CLF 13 454 Safety cable attachment point Display Handle AC mains power input AC mains power through Antenna Wireless Solutions CLF ARES XS Omega bracket with Quicklock 520114 Optional ARES XS ...

Страница 7: ...it must be equipped with a fuse or circuit breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or cut power as this may cause arcing at the ter...

Страница 8: ...xture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput sockets and yellow connectors must be used to supply power at the fixture s power input sockets No matter what the AC mains power voltage is do not connect more than ten the fixture in total including the first fixture to AC mains power in one interconnected daisy chain using power input and t...

Страница 9: ... can support at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point...

Страница 10: ...gured by using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the address The main screen will show a dot and the backlight will be switched off when a DMX signal is detected The fixture is fully RDM ready So when you are using a RDM ready console you can address the unit and read out its complete status For RDM functions please refer to the...

Страница 11: ... 17ch 23ch 24ch RGBW Strobe Dimmer Function set Macro color CCT LED block Dimmer LED block RGBW LEDblock Dimmerspeed Effect Dimmer Auto speed Control mode DMX control mode is selected in the CONTROL MODE menu The fixture has 7 DMX control modes ...

Страница 12: ...y Value must be held for 3 seconds to activate 5 Save Correction 000 254 255 No function Save Correction Value must be held for 3 seconds to activate 6 Red 000 255 0 100 7 Green 000 255 0 100 8 Blue 000 255 0 100 9 White 000 255 0 100 3 FACTORY calibration mode Fixture is calibrated in the factory by radiant machine ECNKDTCVKQP options There are three options for Static color Auto show The auto fu...

Страница 13: ...ON MANUAL FACTORY Color calibration mode off Manual calibration mode RGBW to white is custom calibration Factory calibration mode RGBW to white is factory calibration Refresh rate Controls the Flicker frequency of the fixture 600 1200 2400 4800 LCD brightness Set the LCD display brightness 1 10 DMX HOLD DMX HOLD NO DMX HOLD The fixture will remember on last values when you disconnect DMX The fixtu...

Страница 14: ...WWW CLF LIGHTING COM 12 0 dmx protocols 4 CH Function Value Setting Remark 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 White 000 255 0 100 ...

Страница 15: ...9 170 174 175 179 180 184 185 189 190 194 195 239 240 244 245 249 250 255 No function 1 SILENT MODE level 1 70 fan speed 1 SILENT MODE level 2 40 fan speed 1 SILENT MODE level 3 20 fan speed No function 1 Fan mode FULL 1 Fan mode REGULATED 1 Fan mode SILENT No function 1 Calibrated color output mode COLOR CALIB ON 1 output mode ON 1 Raw color output mode COLOR CALIB OFF No function 1 Normal dimmin...

Страница 16: ...4 155 159 160 164 165 169 170 174 175 179 180 184 185 189 190 194 195 239 240 244 245 249 250 255 No function 1 SILENT MODE level 1 70 fan speed 1 SILENT MODE level 2 40 fan speed 1 SILENT MODE level 3 20 fan speed No function 1 Fan mode FULL 1 Fan mode REGULATED 1 Fan mode SILENT No function 1 Calibrated color output mode COLOR CALIB ON 1 output mode ON 1 Raw color output mode COLOR CALIB OFF No ...

Страница 17: ... 159 160 169 170 179 180 189 190 199 200 255 No function Auto program 1 Auto program 2 Auto program 3 Auto program 4 Auto program 5 Auto program 6 Auto program 7 Auto program 8 Auto program 9 Auto program 10 Auto program 11 Auto program 12 Auto program 13 Auto program 14 Auto program 15 Auto program 16 Auto program 17 Auto program 18 Auto program 19 Auto program 20 Auto program 1 19 cycle 11 Speed...

Страница 18: ... 1 Blue 1 000 255 0 100 4 LED block 1 White 1 000 255 0 100 5 LED block 2 Red 2 000 255 0 100 6 LED block 2 2 Green 000 255 0 100 7 LED block 2 Blue 2 000 255 0 100 8 LED block 2 White 2 000 255 0 100 9 LED block 3 Red 3 000 255 0 100 10 LED block 3 3 Green 000 255 0 100 11 LED block 3 Blue 3 000 255 0 100 12 LED block 3 White 3 000 255 0 100 ...

Страница 19: ...0 174 175 179 180 184 185 189 190 194 195 239 240 244 245 249 250 255 No function 1 SILENT MODE level 1 70 fan speed 1 SILENT MODE level 2 40 fan speed 1 SILENT MODE level 3 20 fan speed No function 1 Fan mode FULL 1 Fan mode REGULATED 1 Fan mode SILENT No function 1 Calibrated color output mode COLOR CALIB ON 1 output mode ON 1 Raw color output mode COLOR CALIB OFF No function 1 Normal dimming sp...

Страница 20: ...rogram 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 255 No function Auto program 1 Auto program 2 Auto program 3 Auto program 4 Auto program 5 Auto program 6 Auto program 7 Auto program 8 Auto program 9 Auto program 10 Auto program 11 Auto program 12 Auto program 13 Auto program 1...

Страница 21: ... 170 174 175 179 180 184 185 189 190 194 195 239 240 244 245 249 250 255 No function 1 SILENT MODE level 1 70 fan speed 1 SILENT MODE level 2 40 fan speed 1 SILENT MODE level 3 20 fan speed No function 1 Fan mode FULL 1 Fan mode REGULATED 1 Fan mode SILENT No function 1 Calibrated color output mode COLOR CALIB ON 1 output mode ON 1 Raw color output mode COLOR CALIB OFF No function 1 Normal dimming...

Страница 22: ... 255 LED block 3 Red 3 0 100 CH 5 must activated 19 Green 3 000 255 LED block 3 0 100 Green 3 CH 6 must activated 20 Blue 3 000 255 LED block 3 3 0 100 Blue CH 7 must activated 21 White 3 000 255 LED block 3 3 0 100 White CH 8 must activated 22 Auto program 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 17...

Страница 23: ...9 180 184 185 189 190 194 195 239 240 244 245 249 250 255 No function 1 SILENT MODE level 1 70 fan speed 1 SILENT MODE level 2 40 fan speed 1 SILENT MODE level 3 20 fan speed No function 1 Fan mode FULL 1 Fan mode REGULATED 1 Fan mode SILENT No function 1 Calibrated color output mode COLOR CALIB ON 1 output mode ON 1 Raw color output mode COLOR CALIB OFF No function 1 Normal dimming speed of chang...

Страница 24: ... Green 3 20 Blue 3 000 255 LED block 3 3 0 100 Blue 21 White 3 000 255 LED block 3 3 0 100 White 22 Fade 3 000 255 LED block 3 Fade dimmer speed 23 Auto program 000 009 010 019 020 029 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 149 150 159 160 169 170 179 180 189 190 199 200 255 No function Auto program 1 Auto program 2 Auto program 3 Auto program 4...

Страница 25: ...ter Dimmer Speed Normal Default Normal Smooth KEY Lock ON OFF Default OFF W DMX ON Default ON OFF RESET Calibration NO CALIBRATION Default FACTORY MANUAL FACTORY Refresh rate 600 1200 2400 4800 Default 600 LCD brightness Level 1 10 DMX HOLD DMX HOLD Default DMX HOLD NO DMX HOLD 5 AUTO AUTO 1 20 Speed 0 20 Default AUTO 1 Speed 0 6 INFO Software type V X XX Usage time TOTAL Xxxx hours RESET Use time...

Страница 26: ...11 CLF 15 070 CLF 15 068 CLF 15 025 CLF 15 002 CLF 15 069 CLF 15 029 CLF 15 039 CLF 15 005 CLF 13 459 CLF 13 448 CLF 13 405 CLF 13 406 CLF 15 010 CLF 15 008 CLF 13 455 CLF 14 028 CLF 13 456 CLF 14 027 CLF 15 014 CLF 15 027 CLF 15 028 CLF 15 067 CLF 15 064 CLF 15 003 CLF 15 037 CLF 15 024 CLF 15 040 CLF 15 004 CLF Barndoor set Ares xs Description CLF Barndoor set Ares xs CLF Front cover Ares xs CLF...

Страница 27: ...imum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socket AC power throughput PowerCON TRUE 1 output socket DMX data in out 5 pin locking XLR 3 pin optional with CLF 13 453 CLF 13 454 Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 300 W Power supply unit Auto ranging electronic switch mode Power consumption all...

Страница 28: ...EOH EXW NHHS LQ PLQG WKDW LW FDQ EULQJ GDPDJH WR DJLQJ PDWHULDOV DQG DႇHFW WKH FRDWHG VXUIDFH L H VWDLQOHVV VWHHO 5XEEHU VHDOLQJV ZLOO EH QHJDWLYHO DႇHFWHG DIWHU ORQJ WHUP 89 H SRVXUH DQG VKRXOG EH FKHFNHG E TXDOL HG VHUYLFH WHFKQLFLDQV RYHU WLPH 7LJKWHQ VFUHZV WRR KDUG ZLOO DOVR DႇHFW WKH 3 UDWLQJ solid object Moisture IP Ingress Protection 6 5 Protected against a solid object greater than 50mm s...

Страница 29: ...WWW CLF LIGHTING COM CLFLIGHTING ARES XS ...

Отзывы: