background image

1942322

  V1.5 

27 June 2022 

 

Clevertest and Clevertest Plus 

 

Refer to the supplementary operation guide supplied with the Product.

 

 

 

After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red 
flashing for a period up to 2 minutes. 
 

 
Zoneworks, HIVE (HV/HVG) and DATA Monitored Options

 

Fittings with part numbers -ZW

, -HV, -HVG, -DATA 

are fitted with Zoneworks communications modules 

(nodes). These fittings are monitored using either Powerline Carrier Technology that utilize the power 
cable to provide data communication, RF transceiver modules operating in the ISM band or a dedicated 
data cable to/from data routers installed on a dedicated data trunk connected to a central Server (can 
also be connected via Ethernet/Internet/Fibre). Zoneworks software on the server is used to monitor, 
coordinate testing and collate test data from each fitting. Zoneworks Fittings can be commissioned by 
a single push of the test switch or by scanning the supplied barcode. The LED Test Switch indicator 
provides a multifunction indication of the status of the fitting during testing and normal operation. 
 

Option 

State 

LED Operation 

ZW, HV, HVG, 
DATA 

Commissioned 

LED on Solid (Green) 

ZW, DATA 

Un-commissioned 

Batt plugged-in:

 yellow 1s, green 1s 

Batt unplugged:

 red 1s, off 1s 

HV, HVG 

Un-commissioned 
With network connectivity 

Batt plugged-in:

 yellow 1s, green 1s 

Batt unplugged:

 red 1s, off 1s 

HV, HVG 

Un-commissioned 
Without network connectivity 

Batt plugged-in:

 yellow 250mS, green 

250mS, yellow 250mS, green 250mS, 
green 1s 

Batt unplugged:

 red 250mS, off 

250mS, red 250mS,off 250mS, off 1s 

ZW, DATA 

Emergency Light Test In Progress 

LED flashes at yellow 5s , 0ff 1s 

HV, HVG 

Emergency Light Test In Progress 

LED flashes at yellow 1s , 0ff 1s 

 

In the case of the DATA version a 2-

way “figure 8” cable and terminal block facilitates the connection 

to the DATA network via a multi-drop bus (daisy chain connection).  For further information of 
installation of a Zoneworks system, please refer to the Zoneworks Users Guide and Commissioning 
Guide (incl. DATA version)  

 
DALI EM Option

 

Luminaires  with  part  numbers  having 

-DALI 

are  fitted  with  DALI  modules  (nodes)  that  facilitate 

connection and integration to 3

rd

 Party Lighting Control Systems.  Before installing the -DALI luminaire, 

please  confirm  that  the  Lighting  Control  System  has  the  capability  to  monitor  DALI  Emergency 
Luminaires.  The -DALI fitting will be addressed and configured into the control system by the Lighting 
Control System Commissioning Technicians and not Clevertronics.   

State

 

LED Operation

 

Commissioned/ Un-commissioned 

LED on Solid (Green) 

Emergency Light Test in progress 

LED flashes at 1s On (Yellow) & 1s Off 

“IDENTIFY COMMAND” 

Lamp and Status LED Flash for 30 seconds 

 
A 2-

way “figure 8” cable and terminal block facilitates the connection to the DALI network.  DALI 

connections are marked as Da Da. 
 
 

 

 
 
 

LP

™ LIFELIGHT Recessed Splash Proof 

Emergency Light

 

Installation & Maintenance Instruction Leaflet

 

 

Designed in Australia to comply with the 
requirements of AS2293.3: 2005 and AS/NZS 
CISPR15: 2011. 
 

NOTE: Standard product codes with this symbol        
are enabled with Clevertest Plus capability.  Please 
refer to the operation guide supplied with the product 
for details.

 

Victoria (Head Office & Manufacturing) 

Website:

 

www.clevertronics.com.au 

Email:

 

[email protected]

 

Phone:

 +61 3 9559 2700  

Fax:

 +61 3 9559 2799 

News South Wales

 

Phone: 

+61 2 8805 6400

 

Fax:    

+61 2 8805 6444

 

Queensland

  

Phone:

  +61 7  3442 9700 

Fax:

     +61 7  3442 9777 

South Australia/Northern Territory

  

Phone:

 +61 8 8301 8800 

Fax:

   +61 8 8351 8286 

Western Australia

  

Phone:

 +61 8 9207 0000 

Fax:

 +61 8 9207 0088 

 

New Zealand 

Phone: +64 800 548 448

 

Models: 

CLIFE-RECSP-zz-xx-yy-vv-ss 

Testing: 

 

 

 

 

Options: 

 

Manual Test  

 

xx = Blank 

 

4 Hour runtime vv=4HR 

Zoneworks 

 

xx = ZW 

 

Corridor Lens  zz=CL 

Zoneworks DATA    

xx = DATA 

 

Tamper Proof  yy = TP 

Zoneworks HIVE   

xx = HV/HVG 

 

Custom Colour ss = CC 

DALI Registered      

 

xx = DALI 

 

 

 

Clevertest 

 

xx = CT 

  

 

(

NOTE: -CT Products supplied with the Clevertest Plus Symbol        are activated with Clevertest 

PLUS capability. Please refer to the operation guide supplied with the product for details). 

Spare Parts:  

1100760 

Replacement Emergency LED Lamp 

1100759 

Replacement Emergency LED Lamp 

(-CL)

 

1550010   

Replacement Battery 

1550230 

Replacement Battery 

(-4HR)

 

AUM02370010001 

Replacement Emergency Driver 

AUM02870080001 / 

AUM02970020001

 

Replacement Emergency Driver (-

HV / -HVG)

 

AUM02270150102 

Replacement Emergency Driver 

(-DALI) 

Important:

 

It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before installation, 
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in 
accordance with the relevant Australian and International Standards.

 

 

 

 

 

 

 

Отзывы: