1943041
V1.6
19 May 2022
Instruction Sheet Template - V1.2
–
Updated 06/10/2021
Installation:
The LP Ultrablade Pro LED Exit (CUBPRO) is a recessed ceiling mount fitting. The CUBPRO can be
attached directly to any solid surface, or to a ceiling tile with the integrated clamping mechanisms. The
CUBPRO comes with an attached Flex and Plug. Please follow the steps below to install the CUBPRO
Exit:
•
If replacing an Ultrablade, an Ultrablade to Ultrablade Pro adapter 2740054 (sold separately)
is required)
•
Create a cut-out (350mm x 48mm) in the mounting surface.
•
Route the power cord to the mains connection and connect the 240VAC supply.
•
Insert the CUBPRO into the ceiling cavity tighten the (4) clamping screws.
•
The standard maximum ceiling thickness is 18mm. Trim Clamp as per below image for ceiling
thickness up to 25mm.
•
Alternately, fix the CUBPRO to a solid surface using (4) screws through the surface material.
•
Install the cover plate.
•
Apply power to the fitting and test.
•
If the CTP capabilities are activated, please affix the CTP status label to a visible surface and Four
Segment Marking on
the product will include an ‘’F’’ in third segment block.
Dimensions:
Changing EXIT Legend Inserts
:
The Ultrablade Pro Exit comes with an assortment of standard legends.
1.
To remove the legend, grasp the centre of the bottom trim piece and pull down slightly to
expose the legend edge. See photo.
2.
Grasp the bottom edge of the legend and slide the existing legend out of the blade, while
working the edges out along the sides.
3.
Slide the new legend into the blade, ensuring to fit the edges into the sides then slide the
legend to the top of the blade. Insert one bottom corner then the other. Slide the legend down
into the bottom trim.
Testing:
Once connected to the 240V mains supply, the unit must be allowed to charge the battery for at least 24
hours. Conduct the following tests:
•
For the first test, the emergency lamp must remain illuminated for at least 2 hours after
disconnection from the mains supply.
•
Subsequent tests require the unit to illuminate for at least 90 minutes. The results of all tests are
required to be recorded in a service logbook, which is to be kept on-site at all times. If the unit fails
to remain illuminated for the requisite time, remedial action must be taken to repair the situation
and once completed, the unit must pass a subsequent test. For more specific information, please
refer to the current edition of the AS 2293.3 Standard.
Ultrablade Maintenance:
LED Lamp Replacement:
•
Use only the LED Strip recommended in
the Spares Parts list of this instruction.
•
Disconnect battery from LED driver pack
and cut cable tie to remove.
•
Disconnect the signal cable from LED strip,
loosen screw and remove the mains driver
pack.
•
Remove 4 self-tapping screws and unclip
the LED strip.
•
Install the new LED strip following the
above procedure in reverse.
Battery Replacement:
•
Use only the battery recommended in the
Spares List on this instruction.
•
Remove the cable ties holding the battery,
un-plug the lead from the battery connector
remove the old battery.
•
Plug the new battery into the battery
connector.
•
Secure the battery using suitable cable ties
Trouble Shooting:
Below are a list of common problems and their
possible causes.
Fault:
The Green LED Test Switch
indicator is not illuminated.
Check: A.C. is connected and is turned on.
Battery is connected
Test Switch for damage.
Fault:
Lamp does not illuminate in
emergency mode.
Check: A.C. is connected.
Lamp is correctly inserted.
Battery is connected
Fault:
Lamp illuminates in emergency
mode, but only stays on for a short
period.
Check:
Battery has been allowed to charge for
at least 24 hours.
Battery for damage.
Rated Emergency Lumen Output in accordance with AS2293.1, not applicable
for
–TH (theatre) version (refer to spacing tables for installation positions):
Refer to the Technical Label for classification information.
Caution:
On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during
construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries
discharged or “cycled”. The battery in this fitting has been selected to give excellent long-life
performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-
life performance and may lead to premature battery failure. Battery warranty claims, as a result of such
abuse, are specifically EXCLUDED from Clevertronics warranty terms.
Warranty:
For Product Warranty information and Terms and Conditions of Sales please refer to our website
http://clevertronics.com.au/terms-conditions-sale-australia-nz/