1942498
V1.2
20 May 2022
Clevertest and Clevertest Plus
Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
Note: To scan the Status LED on the luminaire, the diffuser will require removal.
Status LED Note:
The Status LED is High Brightness and may appear as two separate spots as
illustrated. If Red and Green are seen at the same time, this needs to be taken
as Yellow in the Cleverest Plus operation guide.
Zoneworks, HIVE and DATA Monitored Options
Fittings with part numbers -ZW
, -HV/-HVG, -DATA
are fitted with Zoneworks communications modules
(nodes). These fittings are monitored using either Powerline Carrier Technology that utilize the power
cable to provide data communication, RF transceiver modules operating in the ISM band or a dedicated
data cable to/from data routers installed on a dedicated data trunk connected to a central Server (can
also be connected via Ethernet/Internet/Fibre). Zoneworks software on the server is used to monitor,
coordinate testing and collate test data from each fitting. Zoneworks Fittings can be commissioned by
a single push of the test switch or by scanning the supplied barcode. The LED Test Switch indicator
provides a multifunction indication of the status of the fitting during testing and normal operation:
Option
State
LED Operation
ZW, HV, HVG,
DATA
Commissioned
LED on Solid (Green)
ZW, DATA
Un-commissioned
Batt plugged-in:
yellow 1s, green 1s
Batt unplugged:
red 1s, off 1s
HV, HVG
Un-commissioned
With network connectivity
Batt plugged-in:
yellow 1s, green 1s
Batt unplugged:
red 1s, off 1s
HV, HVG
Un-commissioned
Without network connectivity
Batt plugged-in:
yellow 250mS,
green 250mS, yellow 250mS, green
250mS, green 1s
Batt unplugged:
red 250mS, off
250mS, red 250mS,off 250mS, off 1s
ZW, DATA
Emergency Light Test In
Progress
LED flashes at yellow 5s , 0ff 1s
HV, HVG
Emergency Light Test In
Progress
LED flashes at yellow 1s , 0ff 1s
In the case of the DATA version a 2-way “figure 8” cable and terminal block facilitates the connection
to the DATA network via a multi-drop bus (daisy chain connection). For further information of
installation of a Zoneworks system, please refer to the Zoneworks Users Guide and Commissioning
Guide (incl. DATA version)
DALI EM Option
Luminaires with part numbers having
-DALI
are fitted with DALI modules (nodes) that facilitate connection
and integration to 3
rd
Party Lighting Control Systems. Before installing the -DALI luminaire please confirm
that the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The -DALI
luminaire will be addressed and configured into the control system by the Lighting Control System
Commissioning Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned LED on Solid (Green)
Emergency Light Test in progress LED flashes at 1s On (red & green) & 1s Off
“IDENTIFY COMMAND”
Lamp and Status LED Flash for 30 seconds
A 2-way “figure 8” cable and terminal block facilitates the connection to the DALI network OR a 5/6way
“structured wiring system” lead and plug facilitating the power and DALI connection. DALI connections
are marked as Da Da.
LP™ Circular Emergency Light
Installation & Maintenance Instruction Leaflet
Victoria (Head Office & Manufacturing)
Website:
Email:
Phone:
+61 3 9559 2700
Fax:
+61 3 9559 2799
New South Wales
Phone:
+61 2 8805 6400
Fax:
+61 2 8805 6444
Queensland
Phone:
+61 7 3442 9700
Fax:
+61 7 3442 9777
South Australia/Northern Territory
Phone:
+61 8 8301 8800
Fax:
+61 8 8351 8286
Western Australia
Phone:
+61 8 9207 0000
Fax:
+61 8 9207 0088
New Zealand
Phone:
+64 800 548 448
Designed in Australia to comply with the
requirements of AS/NZS 2293.3 2018 and AS/NZS
CISPR15: 2017
NOTE: Standard product codes with this symbol are
enabled with Clevertest Plus capability. Please refer to
the operation guide supplied with the product for details.
Models:
CCIRC-yy-xx
Testing:
Options:
Manual Test
xx = Blank
DALI Driver
yy = DD
Zoneworks
xx = ZW
Hi/Lo Control through
Microwave Sensor
yy = MS-HL
Z/W DATA
xx = DATA
DALI Registered.
xx = DALI
Hive
xx = HV/HVG
Spare Parts:
1550010
Replacement Battery
8011800
Replacement Emergency LED
1330091
Replacement 240V Driver
AUM02870500001
Replacement Emergency Driver
(-HV)
AUM02370470001 Replacement Emergency Driver
AUM02970150001 Replacement Emergency Driver
(-HVG)
Important:
It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
Note:
This luminaire (with reinforced insulation between control/LED terminal and AC supply) contains non-user
replaceable light source and battery - to be replaced (if required, refer installation instructions for
battery/lamp replacement) by Clevertronics service personnel/agents or a registered electrician.