manualshive.com logo in svg
background image

1943040 

V1.0 

6 August 2019 

 

Installation:

 

The CLP Ultrablade Pro LED Exit (CUBPRO) is a recessed ceiling mount fitting. The CUBPRO can be 
attached directly to any solid surface, or to a ceiling tile with the integrated clamping mechanisms. The 
CUBPRO comes with an attached Flex and Plug. Please follow the steps below to install the CUBPRO 
Exit: 

 

Create a cut-out (350mm x 48mm) in the mounting surface.  

 

Route the power cord to the mains connection and connect the 240VAC supply. 

 

Insert the CUBPRO into the ceiling cavity tighten the (4) clamping screws.  

 

Alternately, fix the CUBPRO to a solid surface using (4) screws through the surface material. 

 

Install the cover plate. 

 

Apply power to the fitting and test. 

 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by 
the manufacturer or his service agent or a similar qualified person to avoid a hazard. 

 

This luminaire contains non-user replaceable light source and battery. 

 

Terminal block not included. Installation may require advice from a qualified person. 

 

Recommended specifications of terminal block for connecting leads: 

 

Type of Terminal: Screw Terminal  

 

Number of Terminals: 2-Pin 

 

Rated Voltage: 250 V 

 

Rated Connecting Capacity: 10A 

 

If the CTP capabilities are activated, please affix the CTP Status Label to a visible surface. 
 

Networking: 

When installing the product on a monitored network, (ZONEWORKS, DATA, DALI) simply insert the 
relevant Smart Node PCA. 

Dimensions: 

Luminaire Dimensions: 

380mm x 220mm 

Cover Plate: 

 

385mm x 67mm 

Ceiling Cut-out: 

 

350mm x 48mm  

Minimum Depth 

 

80mm 

 

 

Changing EXIT Legend Inserts

:

  

 

The Ultrablade Pro Exit comes with an assortment of standard legends.  
1. 

To remove the legend, grasp the centre of the bottom trim piece and pull down slightly to expose the legend 
edge. See photo. 

2. 

Grasp the bottom edge of the legend and slide the existing legend out of the blade, while working the edges out 
along the sides. 

3. 

Slide the new legend into the blade, ensuring to fit the edges into the sides then slide the legend to the top of the 
blade. Insert one bottom corner then the other. Slide the legend down into the bottom trim.

 

 

 
Testing Procedure:

 

When the unit is connected to the un-switched active, it must be allowed to charge the battery for at 
least 24 hours. Conduct the following tests: 
 

 

The emergency lamp must illuminate for at least 180 min after disconnection from the mains. The 
results of all tests are required to be recorded in a service logbook, which is to be kept on-site at all 
times. If the unit fails to illuminate for the requisite time, remedial action must be taken to repair the 
situation and once completed, the unit must pass a subsequent test.  

 

 

Press and hold Test Button or switch Off Mains Supply, check that the emergency lamp is On. 

 

 

Release the Test Button or Switch On Mains Supply, check that the emergency lamp is Off (Non-
maintained operation). 

 
Ultrablade Maintenance: 

 

LED Lamp Replacement:

 

 

Use only the LED Strip recommended in the 
Spares Parts list of this instruction. 

 

Disconnect battery from LED driver pack and 
cut cable tie to remove. 

 

Disconnect the signal cable from LED strip, 
loosen screw and remove the mains driver 
pack. 

 

Remove 4 self-tapping screws and unclip the 
LED strip. 

 

Install the new LED strip following the above 
procedure in reverse.

 

 

Battery Replacement:

 

 

Use only the battery recommended in the 
Spares List on this instruction. 

 

Remove the cable ties holding the battery, 
un-plug the lead from the battery connector 
remove the old battery.  

 

Plug the new battery into the battery 
connector.  

 

Secure the battery using suitable cable ties 

 

Trouble Shooting: 

Below are a list of common problems and their 
possible causes. 

 
Fault:  

The Green LED Test Switch indicator 
is not illuminated.

 

Check:   A.C. is connected and is turned on. 
 

Battery is connected 
Test Switch for damage. 
 

Fault:  

Lamp does not illuminate in 
emergency mode. 

 

Check:   A.C. is connected. 
 

Lamp is correctly inserted. 

 

Battery is connected 

 

Fault:  

Lamp illuminates in emergency 
mode, but only stays on for a short 
period. 

Check: 

Battery has been allowed to charge for 
at least 24 hours. 

 

Battery for damage.

 

 

Warranty:

 

For Product Warranty information and Terms and Conditions of Sales please refer to our website 

https://clevertronics.co.uk/product-warranty-statement/

 

 