5
Installation:
Chime Jumper Settings.
The combined settings of the PCB jumpers JP1 and JP2 selects the chime as
follows:
Terminal Block
Designation
Description
TB7
Tone 3
Switch closure across these two
terminals will activate the GMT pips.
TB7
Tone 4
Switch closure across these two
terminals will activate the single
tone signal.
TB6
Tone 5
Switch closure across these two
terminals will activate the chime
signal.
TB5
SIG OUT
These two terminals provide the
audio tone signal output which is
suitable for line level inputs of P.A.
amplifiers.
JP1
JP2
2 Chimes (Default)
1 to 2
2 to 3
4 Chimes descending
2 to 3
2 to 3
4 Chimes ascending
2 to 3
1 to 2
Random
1 to 2
1 to 2
Connection to the tone activation terminals must
be by means of 2-core screened cable. The
screen must be connected at the TPG-5 end
only to terminal block TB8 that is marked ‘TONE
I/P SCREENS’, the other end of the screen must
be left open i.e., not connected.
TPG-5A