Clever Little Box TPG-5 Скачать руководство пользователя страница 1

TPG-5

Tone Generator

User Instructions

Tone Pulse Generator

Содержание TPG-5

Страница 1: ...TPG 5 Tone Generator User Instructions Tone Pulse Generator ...

Страница 2: ...l be generated once and then stop If the external contact closure to any of the Tones 1 to 4 is momentary the activated tone will be present for approximately 6 seconds and then stop If the external contact closure to any of the tones 1 to 4 is latched held closed the activated tone will be present until such time that the contact is opened plus an additional period of up to 6 seconds A set of vol...

Страница 3: ...sure S P C O rating 1A 24v DC 0 5A 125v AC Connections Screw terminals on PCB Power consumption 3VA 240v AC 50mA 24v DC Dimensions mm 162 H x 220 W x 44 D mm Weight 1 8kg CIE Group reserves the right to alter the above specifications without prior notice TPG 5 PIR SWITCH BUTTON RELAY ACTIVATION OF MESSAGE VIA AUX IN AMPLIFIER TU16A Suggested System Diagram ...

Страница 4: ...tone is required to be continuous i e active for the period that the switch is latched ON Tone 3 Tone 3 produces Greenwich Mean Time pips 5 short 1 long Fit a momentary type push button switch for this tone Automatic reset of the signal takes place at the end of the pips Tone 4 Tone 4 produces a single tone signal Activation is by remote switch operation to TONE 4 input Fit a momentary type push b...

Страница 5: ...ese two terminals will activate the chime signal TB5 SIG OUT These two terminals provide the audio tone signal output which is suitable for line level inputs of P A amplifiers JP1 JP2 2 Chimes Default 1 to 2 2 to 3 4 Chimes descending 2 to 3 2 to 3 4 Chimes ascending 2 to 3 1 to 2 Random 1 to 2 1 to 2 Connection to the tone activation terminals must be by means of 2 core screened cable The screen ...

Страница 6: ...24v DC input supply terminals 0v TB4 Set of potential free relay contacts for control of external equipment Relay is energised during tone activation NO Normally Open contact NC Normally Closed contact COM Common contact WARNING Under no circumstances must any wiring or maintenance be carried out to the unit whilst the mains power is connected External wiring for tones 1 to 5 activation must be ru...

Страница 7: ...7 Notes ...

Страница 8: ...st Bulwell Nottingham NG6 8WB England T 44 0 115 977 0075 F 44 0 115 9770081 E audio cie group com W www cie group com Registered in England No 2761780 UKAS QUALITY MANAGEMENT 003 Take a look at our full Clever Little Box product range online at ...

Отзывы: