UTILITY CONNECTIONS
ELECTRIC
1 Fan & Controls,
1 Phase
(NOT TO SCALE)
SECT.
IV
PAGE
18
1007
Litho in U.S.A.
GAS
COLD WATER
DRAINAGE
C1 C2
C1
C2
D
35 psi minimum
60 psi maximum
3
⁄
8
˝ Dia. NPT for
Generator (for water
treatment connection)
3
⁄
8
˝ Dia. NPT for
Condenser
1
1
⁄
2
˝ dia.
Do not connect other units to this drain
Drain must not be located beneath the steamer
itself. Preferred floor drain location should be a
minimum distance (from the unit) of at least 12”
from the left side, 12" from the right side, 6”
from the front and 6" from the rear.
Do not use PVC pipe
75,000 BTU - 1 Compartment, 125,000 BTU - 2 Compartments
C1 C2
C1
C2
C1 C2
C1
C2
SUPPLY PRESSURE
NATURAL
PROPANE
4.00˝ W.C. minimum
12.00˝ W.C. minimum
14.00˝ W.C. maximum
14.00˝ W.C. maximum
Manufacturer must be notified if unit will be used above 2,000
ft. altitude.
10 — 12˝ x 20˝ x 2
1
⁄
2
˝ Cafeteria Pans or
20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
2
6 — 12˝ x 20˝ x 4˝ Cafeteria Pans
TOTAL CAPACITY
(2 Compartments)
Electrical Supply
Drain: 1.50˝ Dia.
Flue Gas Exhaust from Boiler
Cold Water Supply for Condenser 3/8˝ Dia. NPT
Inlet for Generator Deliming Solution
Flue Diverter (if required)
Cold Water Supply for Generator and Water Injection.
Gas Supply .75˝ Dia.
3/8˝ Dia. NPT (for water treatment conn.)
Unit comes with a 50 Mesh Water Strainer (installation required)
A
B
C
H
G
F
E
D
Volts Watts Amps Wire
120
200
2.0
2
** Do not connect to GFI
outlet. See note below.
Each Compartment has
capacity for:
• Five, 12˝ x 20˝ x 2
1
⁄
2
˝ deep
Cafeteria Pans.
WATER QUALITY
REQUIREMENTS
The quality of water varies
greatly from region to region.
Steam equipment generators
must be drained daily and
chemically descaled periodically
to ensure proper operation. To
minimize service problems
caused by the accumulation of
minerals and chemicals in water
review the following quality
guidelines with a local water
treatment specialist. Inlet water
that is beyond these specified
guidelines should be treated to
achieve these acceptable limits.
Total Dissolved Solids less than
60 ppm, Alkalinity less than 20
ppm, Silica less than 13 ppm,
pH factor greater than 7.5,
Chlorine less than 30 ppm.
NOTES
:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
CLEARANCE
Right - 3”, Left - 3”,
Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
access)
Contact factory for
variances to clearances.