Cleveland SET-15 Скачать руководство пользователя страница 3

GENERAL INFORMATION

These instructions must be retained by the owner/user
for future reference.

The serial plate is located on the right side of the control
housing. Voltage, phase, amperage and wattage are
stated on the plate.

This equipment is built to comply with applicable
standards for manufacturers. Included among those
approval agencies are: UL, NSF, CSA, ETL, and others.
Many local codes exist, and it is the responsibility of the
owner and installer to comply with these codes.

GENERAL INSTALLATION

Check the electrical rating label to ensure that the unit is
the correct voltage, phase, amperage and wattage are
stated on this label.

Observe all clearance requirements to provide air
supply for proper operation, as well as sufficient
clearance for servicing. Keep the skillet area free and
clear of combustibles. Dimensions and clearance
specifications are shown on the specification sheet.

WARNING

: Installation of skillet must be accomplished

by qualified installation personnel, working to all
applicable local and national codes. Improper
installation of product could cause injury or damage,
and void the warranty.

Installation must be in accordance with local codes
and/or the National Electric Code ANSI/NFPA No. 70-
latest edition (USA) or the Canadian Electrical Code
CSA Standard C22.1 (Canada). The skillet must be
electrically grounded by the installer.

Electrically powered skillets require a separate fused
disconnect switch which must be supplied and installed
in the high voltage electrical supply line. The wire
gauge size and electric supply must match the power
requirements specified on the skillet's rating plate. The
conduit-enclosed permanent copper wiring must be
adequate to carry the required current at rated voltage.
Refer to the specification sheet for electrical
specifications and location of electrical connections.

INSPECTION / UNPACKING

1.

Before unpacking visually inspect the unit for
evidence of damage during shipping.

2.

If damage is noticed, do not unpack the unit, follow
"SHIPPING DAMAGE INSTRUCTIONS" shown below.

3.

Carefully remove unit from shipping carton. Remove
any packing material from unit. After carefully
unpacking check for "concealed" damage. If
damage is noticed, follow "SHIPPING DAMAGE
INSTRUCTIONS" shown below.

4.

Check the electrical rating label to ensure that the
unit is the correct voltage, phase, amperage and
wattage are stated on this label.

5.

A protective material has been applied to the
stainless steel panels. This material must be
removed immediately after installation, as heat will
melt the material and make it more difficult to
remove.

SHIPPING DAMAGE
INSTRUCTIONS

If shipping damage to the unit is discovered or
suspected, observe the following guidelines in
preparing a shipping damage claim.

1.

Write down a description of the damage or the
reason for suspecting damage as soon as it is
discovered. This will help in filling out the claim
forms later.

2.

As soon as damage is discovered or suspected,
notify the carrier that delivered the shipment.

3.

Arrange for the carrier's representative to examine
the damage.

4.

Fill out all carrier claims forms and have the
examining carrier sign and date each form.

INSTALLATION

All manuals and user guides at all-guides.com

Содержание SET-15

Страница 1: ...4900 Fax 216 481 3782 Visit our web site at www clevelandrange com Operators Manual Installation Operation Service Skillets Cleveland Enodis SET 15 SET 10 TABLE TOP ELECTRIC SKILLETS MODELS SET 10 SET...

Страница 2: ...RATING LABEL ALL SERVICE MUST BE PERFORMED BY A QUALIFIED CLEVELAND RANGE TECHNICIAN RETAIN THIS MANUAL FOR YOUR REFERENCE WARNING Improper installation adjustment alteration service or maintenance ca...

Страница 3: ...line The wire gauge size and electric supply must match the power requirements specified on the skillet s rating plate The conduit enclosed permanent copper wiring must be adequate to carry the requi...

Страница 4: ...ough the cut out in the rear of the console and fasten to the three connection terminal block Be sure to connect the ground wire to the separate ground terminal connector ground lug Replace the consol...

Страница 5: ...buting it evenly across the cooking surface The indicator light will cycle on and off indicating the elements are cycling on and off The cover should be off for most types of cooking or simmering If c...

Страница 6: ...use Stagnant Water High Pressure Spray Hose Chloride Cleaners Steel Pads Wire Brush CLEANING INSTRUCTIONS CAUTION SURFACES MAY BE EXTREMELY HOT CLEANING INSTRUCTIONS 1 Turn unit off 2 Prepare a warm w...

Страница 7: ...and use a soft cloth or plastic scouring pad 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the industry is providin...

Страница 8: ...1 6 KE51736 Faucet Nut 1 7 KE50335 Adapter Washer Single Pantry only 1 8 FA21008 Hex Nut 2 9 FA11260 Bolt for SET 15 2 FA11258 Bolt for SET 10 2 10 FA31029 Lock Washer 2 1 1 4 4 5 5 6 6 2 3 3 8 7 7 1...

Страница 9: ...500 SPHERICAL WASHER 16 2 FA21024 5 16 18 HEX NUT 16 3 SK2231498 ELEMENT BLOCK ASSEMBLY 208V 3 SK2231499 ELEMENT BLOCK ASSEMBLY 240V 3 4 KE55340 SAFETY THERMOSTAT BIMETAL 1 5 KE50151 2 KNOB FOR HANDLE...

Страница 10: ...SS BAR SUPPORT 4 8 SK2231498 HEATING BLOCK 3 9 KE55340 SAFETY THERMOSTAT BIMETAL 1 10 SK2231699 CROSS BAR WELDMENT 1 11 SK603284 1 2 MALE FEMALE THREADED HEX STANDOFFS 4 12 FA21024 5 16 18 HEX NUT 16...

Страница 11: ...00 BRONZE TRUNNION BEARING 2 12 SK2240800 CONSOLE COVER 1 13 SK2235100 SWITCH TOGGLE ON OFF DPST 1 14 SK50062 RUBBER BOOT 1 15 SK2235000 PILOT LIGHT 1 16 KE55069 2 THERMOSTAT 1 17 SK2234800 BEZEL F 1...

Страница 12: ...MODEL SET 10 ASSEMBLY DRAWING for units built after August 2007 5A 5B 5C 5D 48 All manuals and user guides at all guides com...

Страница 13: ...029 SPRING LOCK WASHER 1 4 2 25 FA10485 HEX BOLT 1 4 20X3 4 2 26 FA31031 HELICAL SPRING LOCK WASHER 3 8 5 27 FA20030 HEX NUT 3 8 16 5 28 SK10197 ROLLER PIN 2 29 KE55069 2 THERMOSTAT 1 30 KE50473 GROUN...

Страница 14: ...00 Washer Spherical 7 9 KE00349 Nut 5 16 18 6 10 SK2276097 Element Block Assembly 1 11 KE55069 2 Thermostat 1 SK2232001 Thermostat Channel 1 12 SK2231500 Washer 2 13 SK2274000 Bolt 5 16 18 x 1 2 2 14...

Страница 15: ...F12 Screw Cover 10 24 x z 2 3 SK2275200 Pilot Light 1 4 SK2235100 Switch Toggle ON OFF 1 5 SK2236600 Rubber Boot 1 6 KE50569 1 Knob Thermostat 1 7 Screw Bezel 6 32 x 5 8 2 SK2234800 Bezel F 1 SK223480...

Страница 16: ...3 8 PAN HEAD 18 8 S S 3 16 SK50056 SWITCH 1 19 FA95074 NYLON ANCHOR 4 21 FA21006 10 24 18 8 S S HEX NUT 8 22 FA30505 2 WASHER NO 10 S S 8 26 FA11052 6 32 X 1 4 S S SCREW SLOT 2 27 SK2274602 3 4 CONNEC...

Страница 17: ...2 HEX BOLT 1 2 13 X 1 1 4 2 12 FA11258 HEX CAP SCREW 1 4 20 X 314 1 13 KE600550 CAM 1 14 FA15019 5 SHOULDER BOLT 1 4 20 1 15 FA95007 9 RETAINING RING 2 16 FA11323 HEX SCREW 5116 18 X 314 2 21 KE60103...

Страница 18: ...it on check for voltage across thermostat Voltage indicates an open circuit Indicating a faulty thermostat 4 Defective high limit thermostat Repeat above procedure used for defective thermostat C PROB...

Страница 19: ...nts blocks Replace as needed NOTE With new element block in place re tighten nuts on spherical washers with a torque wrench to 11ft lbs torque 9 Replace retaining bars retaining back plate and bottom...

Страница 20: ...WIRING DIAGRAM SET 10 SET 15 208 220 or 240V Single or Three Phase for units built prior to November 2005 All manuals and user guides at all guides com...

Страница 21: ...WIRING DIAGRAM SET 10 SET 15 208 380 or 240 415V Three Phase Y Connected for units built prior to November 2005 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 22: ...WIRING DIAGRAM SET 10 SET 15 480V Single or Three Phase for units built prior to November 2005 All manuals and user guides at all guides com...

Страница 23: ...WIRING DIAGRAM SET 10 SET 15 208 220 or 240V Single or Three Phase for units built after November 2005 All manuals and user guides at all guides com...

Страница 24: ...WIRING DIAGRAM SET 10 SET 15 208 380 or 240 415V Three Phase Y Connected for units built after November 2005 All manuals and user guides at all guides com...

Страница 25: ...WIRING DIAGRAM SET 10 SET 15 480V Single or Three Phase for units built after November 2005 All manuals and user guides at all guides com...

Отзывы: