SECT.
XIV
PAGE
14
0907
Litho in USA
Cleveland Range reserves right of design improvement or modification, as warranted.
OPTIONAL
CONNECTIONS
LOCATED ON SIDE
QUICK DISCONNECT
FOR FOOD PUMP
(LOCATION VARIES)
IF KETTLE IS MORE THAN 3'
FROM THE CONTROL PANEL
THEN THE PRODUCT VALVE
SWITCH WILL BE KETTLE MNTD.
(LOCATION VARIES)
4"
OPTIONAL HOT
FILL WATER ONLY
69"
69"
24"
40"
D
E
C
A
B
F
OVER FLOW
PLAN VIEW
DEPTH 18 3/4"
CONTROL PANEL
DUAL CONTROL PANEL
P-DR-CC
P-SR-CC
SINGLE CONTROL PANEL
SIDE VIEW
OPERATIONAL
FRONT
A
D
CR
NOTE:
12 1/2"
DIMENSIONS
MODEL
A
B
C
D
E
F
ELECTRICAL PER KETTLE-
120V/1PH/60Hz
P-KDL-60-CC
32"
52"
45 1/2"
8"
24"
56"
10 AMPS
P-KDL-100-CC
39"
59"
49 1/2"
9"
28"
60"
10 AMPS
P-KDL-150-CC
45"
63"
55 1/2"
9"
30"
66"
10 AMPS
P-KDL-200-CC
49"
67"
57 1/2"
9"
32"
68"
10 AMPS
UTILITY CONNECTIONS
CHILLED
CHILLED
COLD
COLD
WATER
WATER
POTABLE
HOT
CONDENSATE
AIR
INJECTOR
MODEL
INLET
RETURN
WATER
WATER
RETURN
DRAIN
INLET
STEAM
WATER
P-KDL-60-CC
3/4"
3/4"
3/4"
3/4"
1/2"
3/4"
1/2"
3/4"
3/4"
15 GPM
15 GPM
15 GPM
1 CFM
320 lbs/hr
15 GPM
P-KDL-100-CC
1"
1"
3/4"
3/4"
3/4"
1"
1/2"
1"
3/4"
20 GPM
20 GPM
20 GPM
1 CFM
525 lbs/hr
20 GPM
P-KDL-150-CC
1 1/4"
1 1/4"
3/4"
3/4"
1"
1 1/4"
1/2"
1 1/4"
3/4"
20 GPM
20 GPM
20 GPM
1 CFM
780 lbs/hr
20 GPM
P-KDL-200-CC
1 1/4"
1 1/4"
3/4"
3/4"
1"
1 1/4"
1/2"
1 1/4"
3/4"
25 GPM
20 GPM
20 GPM
1 CFM
1050 lbs/hr
20 GPM
** HOT FILL WATER IS OPTIONAL
65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED
**
ELECTRICAL POWER
TO AND FROM
CONTROL PANEL
• CONTRACTOR
MUST CUT ENTRY
HOLE
• TOP OR BOTTOM
POWER ENTRY
RECOMMENDED
• MUST USE PROPER
CONNECTIONS TO
MAINTAIN U.L.
LISTING
(NOT TO SCALE)
MINIMUM CLEARANCE
FOR KETTLES
FRONT
36"
SIDE
12"
REAR
12"
NOTES
: The pressure drop is 12 to 15 PSI for steam and chilled water passing through the kettle.
Air must be dry, clean and free of oil.