NT-100 Peristaltic Pump Filler
Page 9
2.4 Parameter Setting
P = Filling Volume
2.4.1 Push SET button, the screen will show P00000.
2.4.2 Enter the parameter for filling volume (please
see P.4 for instructions).
Ex: After adjusting the parameter to 00250, push SET
again to finish setting the parameter.
P.S This is the indicator volume instead of actual
volume.
2P = Delay time for Auto Mode
In Auto Mode, whenever the machine finishes filling
one bottle, it will fill the next one 2 seconds later
automatically as the setting shows 02.0 in the picture
on the right.
★
This setting is ONLY for Auto Mode.
3E = Delay time for Manual Mode
In Manual Mode, after pushing the start button, the
machine will delay for a certain time and then it will
start filling.
As the picture shows on the left with 00.5, it means
when you push the start button, it will start filling 0.5
second later.
★
This setting is ONLY for Manual Mode.