925 LBSLBS
420 KGS
1000
4" TO 14" W.C.
NAT
190,000
60
15
3
208/240
3.5
Allow 6.00" (152mm)
space
Minimum from rear
and sides when
located near
combustible walls
3.5
3.5
3.5
3.5
1. MANUFACTURER MUST BE NOTIFIED IF UNIT WILL BE OPERATING ABOVE 2,000 FOOT ALTITUDE.
3. ALL VERTICAL DIMENSIONS SHOWN ARE MINIMUM. FEET ARE ADJUSTABLE TO 1 INCH MAXIMUM.
2. CONSULT FACTORY FOR MANUFACTURED GAS.
MKGL-80-T
MKGL-60-T
NOTES:
415
208/240
480
480
9
360
8
8
15
3
3
3
60
60
60
190,000
NAT
190,000
190,000
190,000
LP
NAT
LP
1000 LBS
454 KGS
MKGL-80-T
4" TO 14" W.C.
4" TO 14" W.C.
4" TO 14" W.C.
4" TO 14" W.C.
1000
2500
1000
2500
**
4.00" (102mm)
clearance required if
adjoining equipment
is over 36" high
*
*
*
*
*
*
3.5
3.5
WATER
COLUMN
3.5
3.5
MKGL-40-T
208/240
480
480
208/240
VOLTS
MODEL
SPECIFICATIONS:
DIMENSIONS:
8
15
8
3
3
3
60
60
60
15
AMPS
3
PHASE
60
FREQ
140,000
140,000
140,000
LP
LP
NAT
140,000
BTU
RATING
NAT
TYPE
WEIGHT
SHIPPING
850 LBS
386 KGS
MKGL-40-T
MKGL-60-T
CGA
APPROVALS
4" TO 14" W.C.
4" TO 14" W.C.
SUPPLY
PRESSURE
4" TO 14" W.C.
4" TO 14" W.C.
2500
2500
1000
1000
CU. FT.
BTU PER
**
**
**
AGA
CLEARANCE:
RIGHT: 0
LEFT: 0
REAR: 0
*
*
*
*
*
NSF
CE
MARK
ELECTRICAL SUPPLY:
GAS SUPPLY: (PIPING 3/4 NPT)
63.75”
1619mm
66.63”
1692mm
70.38”
1788mm
25.00”
635mm
48.00”
1219mm
MKGL-40-T
MKGL-60-T
MKGL-80-T
50.50”
1283mm
54.00”
1372mm
25.50”
648mm
26.00”
660mm
MODEL NO.
A
B
48.00”
1219mm
70.00”
1778mm
40.50”
1029mm
13.50”
343mm
77.00”
1959mm
74.00”
1880mm
43.75”
1111mm
44.75”
1137mm
54.00”
1372mm
52.00”
1321mm
14.25”
362mm
15.75”
400mm
CD
E
F
G
14.00”
356mm
23.00”
584mm
24.00”
61mm
25.00”
635mm
13.50”
343mm
14.50”
368mm
14.00”
356mm
27.00”
686mm
25.00”
635mm
30.00”
762mm
28.00”
711mm
28.00”
711mm
26.00”
660mm
14.00”
356mm
14.00”
356mm
HJ
L
KM
53.75”
1365mm
55.00”
1397mm
55.50”
1410mm
69.75”
1772mm
34.00”
864mm
21.00”
533mm
13.00”
330mm
11.75”
298mm
13.25”
337mm
20.50”
521mm
21.63”
549mm
70.00”
1778mm
71.50”
1816mm
35.75”
908mm
35.13”
892mm
NO
P
Q
55.25”
1403mm
26.00”
660mm
61.88”
1572mm
58.13”
1476mm
29.50”
749mm
33.00”
838mm
(I.D.)
R
ST
C
H
A
SHOWN WITH BUTTERFLY VALVE
SHOWN WITH OPTIONAL AIR VALVE
OPTIONAL
AIR VALVE
HANDLE REPLACED
BY SWITCH FOR
POWER TILT OPTION
SEE FLOOR DRAIN
DETAIL
WALL
REMOTE CONSOLE BOX MOUNTING DETAIL (DTCI OPTION)
REAR
OF
UNIT
REAR
OF
UNIT
FEET & FLOOR
DRAIN LOCATION
DETAIL
DETAIL
CHART RECORDER BOX MOUNTING DETAIL (TCR OPTION)
C
B
O
J
T
G
H
K
F
L
E
D
P
P
Q
R
S (I.D.)
N
A
12.00”
305mm
12.00”
305mm
13.00”
330mm
28.00”
711mm
6.00”
152mm
2.50”
64mm
3.50”
89mm
3.50”
178mm
12.00”
305mm
9.00”
229mm
16.00”
405mm
23.75”
603mm
9.00”
229mm
9.75”
248mm
15.00”
381mm
18.13”
460mm
36.00”
914mm
0.56"
14mm
120º
TYP
1.00" (25mm)
MAX. ADJUSTMENT
1.625" (42mm) Ø
FLANGED FOOT DETAIL
0.44" (11mm) Ø
3 HOLES ON
3.125" (80MM) Ø
B.C.D.
4 7/8"
124 Ø mm
FLOOR SLOPE = 1.00" (26mm) per 4' (1220mm)
RECOMMENDED FLOOR SLOPE
PIPE DRAIN RECOMMENDED
min. valve size plus 1.00" (26mm)
6.00" (153mm) RECOMMENDED
4.00" (102mm) MINIMUM
SECT.
XI
PAGE
22
0707
Litho in U.S.A.
NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.