925 LBSLBS
420 KGS

1000

4" TO 14" W.C.

NAT

190,000

60

15

3

208/240

3.5

Allow 6.00" (152mm) 
space 
Minimum from rear 
and sides when 
located near 
combustible walls

3.5

3.5
3.5

3.5

1. MANUFACTURER MUST BE NOTIFIED IF UNIT WILL BE OPERATING ABOVE 2,000 FOOT ALTITUDE.

3. ALL VERTICAL DIMENSIONS SHOWN ARE MINIMUM. FEET ARE ADJUSTABLE TO 1 INCH MAXIMUM.

2. CONSULT FACTORY FOR MANUFACTURED GAS.

MKGL-80-T

MKGL-60-T

NOTES:

415

208/240

480

480

9

360

8

8

15

3

3

3

60

60

60

190,000

NAT

190,000

190,000

190,000

LP

NAT

LP

1000 LBS
454 KGS

MKGL-80-T

4" TO 14" W.C.

4" TO 14" W.C.
4" TO 14" W.C.

4" TO 14" W.C.

1000

2500

1000

2500

**

4.00" (102mm) 
clearance required if
adjoining equipment 
is over 36" high

*

*

*

*

*

*

3.5

3.5

WATER

COLUMN

3.5
3.5

MKGL-40-T

208/240

480

480

208/240

VOLTS

MODEL

SPECIFICATIONS:

DIMENSIONS:

8

15

8

3

3
3

60

60
60

15

AMPS

3

PHASE

60

FREQ

140,000

140,000

140,000

LP

LP

NAT

140,000

BTU

RATING

NAT

TYPE

WEIGHT

SHIPPING

850 LBS
386 KGS

MKGL-40-T

MKGL-60-T

CGA

APPROVALS

4" TO 14" W.C.

4" TO 14" W.C.

SUPPLY

PRESSURE

4" TO 14" W.C.
4" TO 14" W.C.

2500

2500
1000

1000

 CU. FT.

BTU PER 

**

**

**

AGA

CLEARANCE:

RIGHT: 0

LEFT: 0

REAR: 0

*
*

*
*

*

NSF

CE

MARK

ELECTRICAL SUPPLY:

GAS SUPPLY:      (PIPING 3/4 NPT)

63.75”
1619mm

66.63”
1692mm

70.38”
1788mm

25.00”
635mm

48.00”
1219mm

MKGL-40-T

MKGL-60-T

MKGL-80-T

50.50”
1283mm

54.00”
1372mm

25.50”
648mm

26.00”
660mm

MODEL NO.

A

B

48.00”
1219mm

70.00”
1778mm

40.50”
1029mm

13.50”
343mm

77.00”
1959mm

74.00”
1880mm

43.75”
1111mm

44.75”
1137mm

54.00”
1372mm

52.00”
1321mm

14.25”
362mm

15.75”
400mm

CD

E

F

G

14.00”
356mm

23.00”
584mm

24.00”
61mm

25.00”
635mm

13.50”
343mm

14.50”
368mm

14.00”
356mm

27.00”
686mm

25.00”
635mm

30.00”
762mm

28.00”
711mm 

28.00”
711mm

26.00”
660mm

14.00”
356mm

14.00”
356mm

HJ

L

KM

53.75”
1365mm

55.00”
1397mm

55.50”
1410mm

69.75”
1772mm

34.00”
864mm

21.00”
533mm

13.00”
330mm

11.75”
298mm

13.25”
337mm

20.50”
521mm

21.63”
549mm

70.00”
1778mm

71.50”
1816mm

35.75”
908mm

35.13”
892mm

NO

P

Q

55.25”
1403mm

26.00”
660mm

61.88”
1572mm

58.13”
1476mm

29.50”
749mm

33.00”
838mm

(I.D.)

R

ST

C

H

A

SHOWN WITH BUTTERFLY VALVE

SHOWN WITH OPTIONAL AIR VALVE

OPTIONAL

AIR VALVE

HANDLE REPLACED

BY SWITCH FOR

POWER TILT OPTION

SEE FLOOR DRAIN
DETAIL

WALL

REMOTE CONSOLE BOX MOUNTING DETAIL (DTCI OPTION)

REAR 
OF 
UNIT

REAR 
OF 
UNIT

FEET & FLOOR
DRAIN LOCATION
DETAIL

DETAIL

CHART RECORDER BOX MOUNTING DETAIL (TCR OPTION)

C

B

O

J

T

G

H

K

F

L

E

D

P

P

Q

R

S (I.D.)

N

A

12.00”

305mm

12.00”

305mm

13.00”

330mm

28.00”

711mm

6.00”
152mm

2.50”
64mm

3.50”
89mm

3.50”
178mm

12.00”

305mm

9.00”

229mm

16.00”

405mm

23.75”

603mm

9.00”

229mm

9.75”
248mm

15.00”

381mm

18.13”

460mm

36.00”

914mm

0.56"

14mm

120º

TYP

1.00" (25mm)

 

MAX. ADJUSTMENT

1.625" (42mm) Ø

FLANGED FOOT DETAIL

0.44" (11mm) Ø

3 HOLES ON

3.125" (80MM) Ø

B.C.D.

4 7/8"

124 Ø mm

FLOOR SLOPE = 1.00" (26mm) per 4' (1220mm)

RECOMMENDED FLOOR SLOPE

PIPE DRAIN RECOMMENDED
min. valve size plus 1.00" (26mm)

6.00" (153mm) RECOMMENDED
4.00" (102mm) MINIMUM

SECT.

XI

PAGE 

22

0707

Litho in U.S.A.

NOTES

:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.