Cleveland MKDL-100-CC-T Скачать руководство пользователя страница 2

SECT.

XIV

PAGE 

1

1201

Litho in USA

Cleveland Range reserves right of design improvement or modification, as warranted.

MINIMUM CLEARANCE

FRONT

36"

SIDE

12"

REAR

12"

SECT.

XIV

PAGE 

2

0707

Litho in USA

Cleveland Range reserves right of design improvement or modification, as warranted.

F

E

D

G

CONTROL PANEL
ON LEFT SIDE
(OPTIONAL)

B

A

C

H

TOP OF AGITATOR IN RAISED

POSITION

FRONT VIEW

PLAN VIEW

CR

D

A

DIMENSIONS

MODEL

A

B

C

D

E

F

G

H

MKDL-40-CC-T

78 1/4"

58 1/4"

36"

40 3/4"

26"

14 1/4"

70"

69 1/2"

MKDL-60-CC-T

81 3/4"

61 3/4"

36"

44 1/4"

29 1/2"

14 1/4"

69"

72"

MKDL-80-CC-T

85"

65"

36"

46 1/4"

33"

14 1/4"

70"

74 3/4"

MKDL-100-CC-T

89 3/4"

69 3/4"

36"

48 1/2"

35 1/2"

14 1/4"

69 3/4"

82"

MKDL-125-CC-T

94 1/4"

74 1/4"

36"

48 3/4"

40"

14 1/4"

74"

87 1/4"

MKDL-150-CC-T

94 1/4"

74 1/4"

36"

53 1/2"

40"

14 1/4"

78 3/4"

92"

UTILITY CONNECTIONS

CHILLED

CHILLED

WATER

WATER

COLD

HOT

CONDENSATE

AIR

ELEC-

MODEL

INLET

RETURN

WATER

WATER

STEAM

RETURN

DRAIN

INLET

TRICAL

MKDL-40-CC-T

3/4"

3/4"

3/4"

3/4"

3/4", 50 PSI

3/4"

3/8"

1/2"

9.2 AMPS

15 GPM

20 GPM

20 GPM

150 lbs/hr

1 CFM

MKDL-60-CC-T

3/4"

3/4"

3/4"

3/4"

3/4", 50 PSI

3/4"

3/8"

1/2"

12 AMPS

15 GPM

20 GPM

20 GPM

230 lbs/hr

1 CFM

MKDL-80-CC-T

3/4"

3/4"

3/4"

3/4"

3/4", 50 PSI

3/4"

3/8"

1/2"

12 AMPS

15 GPM

20 GPM

20 GPM

300 lbs/hr

1 CFM

MKDL-100-CC-T

3/4"

3/4"

3/4"

3/4"

1 1/4", 35 PSI

1"

3/8"

1/2"

15.3 AMPS

20 GPM

20 GPM

20 GPM

390 lbs/hr

1 CFM

MKDL-125-CC-T

3/4"

3/4"

3/4"

3/4"

1 1/4", 35 PSI

1"

3/8"

1/2"

15.3 AMPS

20 GPM

20 GPM

20 GPM

470 lbs/hr

1 CFM

MKDL-150-CC-T

3/4"

3/4"

3/4"

3/4"

1 1/4", 35 PSI

1"

3/8"

1/2"

15.3 AMPS

20 GPM

20 GPM

20 GPM

570 lbs/hr

1 CFM 

D

1

D

2

B

D

1

D

2

B

D

1

D

2

B

D

1

D

2

B

D

1

D

2

D

1

D

2

D

1

D

208V/
3PH/60Hz

(NOT TO SCALE)

NOTES

: The pressure drop is 12 to 15 PSI for steam and chilled water passing through the kettle. 

Air must be dry, clean and free of oil.