GAS
SHUT-OFF
VALVE
REGULATOR
PIPE
NIPPLE
PRESSURE
REGULATOR
UNIT
GAS
COMBINATION
VALVE
GASKET
GAS
IDENTIFICATION
STICKER
BURNER
MAIN
ORIFICE
MAIN
ORIFICE
FITTING
TO MAIN GAS
SUPPLY
THIS
CO
NTR
OL
HAS
BEE
N
CON
VER
TED
TO L
P
NOTE:
Use thread sealant compatible with propane gas
on all threaded piping connections.
1.
Disconnect electrical connection.
2.
Shut off main gas supply and disconnect kettle from
supply line.
3.
Remove
GAS SHUT-OFF VALVE
from kettle supply
pipe and install
REGULATOR
(pre-set to 10 " W.C.
pressure) supplied in field conversion kit.
4.
Re-install
SHUT-OFF VALVE
using
PIPE NIPPLE
supplied in kit.
5.
Remove side cover from control console.
6.
Remove
PRESSURE REGULATOR UNIT
from
GAS
COMBINATION VALVE
inside console, and replace
with blocked
PRESSURE REGULATOR UNIT
from
kit. Make sure
GASKET
is correctly seated in recess
in
GAS COMBINATION VALVE
during installation.
7.
Tilt kettle. Remove kettle side box cover. Remove
screw securing end of
BURNER
. Remove
BURNER
.
Support
MAIN ORIFICE FITTING
and remove
MAIN
ORIFICE
. Install new orifice from kit.
8.
Replace
BURNER
. Check
MAIN ORIFICE/BURNER
alignment insuring
MAIN ORIFICE
points straight into
the center of the
BURNER
.
9.
Reconnect to gas supply. Turn on propane gas. Tilt
kettle to upright position, turn on power and check all
gas connections for leaks.
10.
Turn off power and main gas supply, and replace all
covers. Attach GAS IDENTIFICATION STICKER to
nameplate.
11.
Place gas conversion label next to rating label.
NOTE:
Place GAS IDENTIFICATION STICKER on
face of GAS COMBINATION VALVE.
Atmospheric Burner Gas Kettles
BTU's per Gas
Water
# of
Hour
Type
Column Orifices
KGT-6-T
34000
NAT
4.2
1
34000
LP
10
1
KGT-12-T
53000
NAT
4.2
1
53000
LP
10
1
KGL-25, KGL-25-T
90000
NAT
4.2
2
90000
LP
10
2
Conversion Parts Required
Part No.
Description
Quantity
KE95549
Conversion Label
1
SE50438
Field Conversion Kit, 6 gallon
1
SE50438-1
Field Conversion Kit, 12 gallon
1
FIELD CONVERSION
INSTRUCTIONS -
Natural Gas to Propane Gas