background image

6

Operating Instructions and Owner’s Manual

Cleveland Iron Works Wood Pellet Fire Stove

UNPACKING & ASSEMBLY

1.  Remove heater from carton. 
2.  Remove all protective packaging applied to heater 

for shipment. 

3.  Check heater for any shipping damage. If any 

damage is found immediately contact the 
manufacturer at 800-251-0001.

 CAUTION: DAMAGED PARTS MAY 

COMPROMISE SAFE OPERATION.

• 

DO NOT INSTALL INCOMPLETE COMPONENTS.

• 

DO NOT INSTALL SUBSTITUTE COMPONENTS.

• 

DO NOT INSTALL DAMAGED COMPONENTS.

4.  Some components are packaged unattached from 

the stove in order to ensure their safety during 
shipping. Please find the protective packaging, likely 
inside the stove door, to proceed with assembly.  

Main Power Cord

The main power cord attaches to the stove at the 
exposed socket in the rear of the stove. Once any 
necessary assembly of the display panel screen is 
complete (PSBF66W only) you may briefly plug your 
stove in make sure that it functions properly before 
proceeding with installation. Unplug the stove once 
you confirm that the display panel works.

 CAUTION: DO NOT LEAVE THE STOVE 

PLUGGED INTO ANY ELECTRICAL SUPPLY 
DURING ASSEMBLY OR INSTALLATION.

Firepot

With the stove unplugged from any power supply, the 
firepot should be inserted into the stove so that it is 
securely positioned and also the hot surface igniter 
should be able to make physical contact with pellets 
that would be held in the firepot. See figure 2 or 3.

Figure 2

 

PS60W and 

PS130W firepot

41

Figure 3 P

SBF66W 

firepot

A cleaning kit is also packaged which facilitates safely 
cleaning the firepot perforations of debris.

Air Intake Kit

Locate the air intake kit packaged with the stove. See 
Figure 4. Take measurements of your space and plan 
for the installation of horizontal venting to the outside 

as may be required per recommendations in “FRESH 
AIR AND VENTILATION REQUIREMENTS 1” on page 

7. Follow all ventilation requirements and guidelines 

specified in “INSTALLATION” on page 6.

Termination Cap

2” Flex Hose

Hose Clamp

Figure 4

 

Intake Kit

Additional Assembly PS60W, PS130W

• 

The door handle: open the door, and screw the 
plastic grip onto the thread of the handle

.

Figure 5

 

Door Handle

Additional Assembly PSBF66W

• 

The display panel: insert the display panel into the 
top and rear of the stove. Be sure that the display 
panel screen is facing towards the front of the stove. 
Secure the screen using two of the provided screws.

• 

The power cord for the display panel

:

 this cord 

should be wrapped up near the top of the stove. 
Insert free end into the back of the display panel 
(see figure 16 on page 14). This wire should 
already be connected to the stoves power board. This 
connection can be checked behind the access plate at 
the bottom and rear of stove .

INSTALLATION

 WARNING: WHEN THIS STOVE IS NOT 

PROPERLY INSTALLED, A HOUSE FIRE MAY 
RESULT. TO REDUCE THE RISK OF FIRE, 
FOLLOW THE INSTALLATION INSTRUCTIONS. 
CONTACT LOCAL BUILDING OR FIRE 
OFFICIALS ABOUT RESTRICTIONS AND 
INSTALLATION INSPECTION REQUIREMENTS 
IN YOUR AREA. 

 WARNING: When this stove is not properly installed, a 
house fire may result. To reduce the risk of fire, follow 
the installation instructions. Contact local building or 
fire officials about restrictions and installation inspec-
tion requirements in your area.

Содержание F500200

Страница 1: ...ERMINE ANY NEED TO OBTAIN A PERMIT OBSERVE ALL LOCAL BUILDING CODES OPERATING INSTRUCTIONS AND OWNER S MANUAL Model PS60W PS130W PSBF66W READ INSTRUCTIONS CAREFULLY Please read this entire manual befo...

Страница 2: ...CH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE STOVE AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE STOVE IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBL...

Страница 3: ...3 04 1 38 Pellet Consumptiovn Rate High LBS HR kg HR 4 01 1 82 5 45 2 47 5 82 2 64 Automatic Mode Duration minimum hours maximum hours 42 5 15 0 62 2 23 9 62 3 11 3 Stove Efficiency 82 3 75 8 82 2 Ou...

Страница 4: ...E THE FLU WITH HEADACHE DIZZINESS AND OR NAUSEA IF YOU HAVE THESE SIGNS STOVE MAY NOT BE WORKING PROPERLY GET FRESH AIR AT ONCE HAVE STOVE SERVICED SOME PEOPLE PREGNANT WOMEN PERSONS WITH HEART OR LUN...

Страница 5: ...pe must be at least 3 76 mm from any wall Finally the area which the wood pellet fire stove is installed shall have a floor to ceiling distance of at least 84 2134 mm FLOORING MATERIAL Floor protectio...

Страница 6: ...he firepot See figure 2 or 3 Figure 2 PS60W and PS130W firepot 41 Figure 3 PSBF66W firepot A cleaning kit is also packaged which facilitates safely cleaning the firepot perforations of debris Air Inta...

Страница 7: ...AL on page 5 Manufactured venting of 3 80 mm diameter of type L or PL which is listed to UL 641 ULC S609 Standard for 650 C Factory Built Chimneys or ULC ORD C441 Install per chimney manufacturer s in...

Страница 8: ...Built Residential Type and Building Heating Appliance UL 103 A International Conference of Building Officials ICBO standards for solid fuel Stoves code approved masonry chimney VENT TERMINATION Instal...

Страница 9: ...r channels separated from combustibles by a minimum of 6 inches 152 mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness...

Страница 10: ...inch diameter rod can enter beyond 4 inches The stove must be on installed on a level surface which can support the weight of the stove The stove must be bolted to the level surface so that it permane...

Страница 11: ...sed with either a UL 103HT US ULC S629 CAN listed manufactured chimney or an approved lined masonry chimney Not all manufactured chimney are UL103 HT ULC S629 listed Home centers hardware stores HVAC...

Страница 12: ...se the pellet sediment debris at the bottom of the pellet container Store pellets in sacks made of environmentally neutral or biologically degradable plastic or from paper 2 3 layers similar to cement...

Страница 13: ...following stages Cleaning Cycle The firepot draws dust ash remenants out Feeding Cycle Pellets will be transported from the Pellet Hopper into the fire pot by the auger This can take 5 to 15 minutes d...

Страница 14: ...ove app SMART STOVE WIFI CONNECTION This stove can be monitored controlled and programmed by using the smart stove app by NHHATC which is available for iOS or android device through the app store Step...

Страница 15: ...ood pellets while maintaining the desired temperature Pressing the ECO button will allow you to toggle whether a specific eco setting is enabled or to turn off the feature entirely ECO 1 The stove shu...

Страница 16: ...reports in Fahrenheit display in the top right of the multi function display screen R Room temperature S Exhaust temperature P Protection Temperature Sensor Press to increase the temperature which the...

Страница 17: ...every day Whichever is more frequent Ash Drawer After 50 bags of wood pellets Passageways After 100 bags of wood pellets Blower After 100 bags of wood pellets CLEANING FIRE POT PAN CAUTION IF STOVE I...

Страница 18: ...any ash or debris build up Build up of debris and ash can restrict the flow of gases which will affect stove performance and failure to remove creosote may result in a dangerous chimney fire FLYASH F...

Страница 19: ...into the most up and most left position of the prepared gasket gutter 5 Continue pressing the replacement gasket clockwise along the gasket gutter until it has wrapped back to where the gasket was pr...

Страница 20: ...ed to the base If a low pressure is created in the firebox by a leak opening the door to the firebox a blocked flue or an unsealed ash drawer then the switch will shut the stove off as a precaution Er...

Страница 21: ...quality fuel in fire pot 2 Check that the firepot is sitting in the holder correctly and that the igniter is not obstructed 3 Check that the exhaust gas temperature sensor switch beside the combustion...

Страница 22: ...e is no problem the blower does not turn on until the stabilization cycle The blower does not turn on during Stabilization Cycle No power in stove or in control panel Check the power and wires Mother...

Страница 23: ...he unit so that it will not start suddenly and then unblock the auger 2 Check that the auger is not blocked If it is blocked remove the cause of the jamming 3 Check that the auger screw fastening the...

Страница 24: ...ted 2 Replace the 30 o C temperature switch The fire extinguishes and the power shuts off continued Requested temperature has been reached This is normal ECO mode behavior The stove will automatically...

Страница 25: ...stion Fan Blower L FUSE N Igniter Auger motor Display panel Vaccum switch Exhaust sensor Protection sensor Room sensor NC NO C k NOTE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE...

Страница 26: ...culation Blower 27 n a Chamber Insulation Cover 28 66613 Safety Sensor 29 n a Motherboard Fixed Plate 30 66631 Rear Cover 31 66615 Power Socket 32 66616 Room Sensor 33 66622 Silicone Rubber Sealing Ri...

Страница 27: ...e Sensor 23 n a Ground Screw 24 66610 Vacuum Switch 25 66611 Silicone Tube 26 66612 Circulation Blower 27 n a Chamber Insulation Cover 28 66613 Safety Sensor NO P N DESCRIPTION 29 n a Motherboard Fixe...

Страница 28: ...36 Right Side Panel 9 66622 Silicone Rubber Sealing Ring 10 66615 Power Socket 11 66637 Motherboard 12 66638 Fire Pot 13 66639 Vacuum Switch 14 66640 Igniter NO P N DESCRIPTION 15 66641 Combustion Blo...

Страница 29: ...ber of your product and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full...