Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).

(NOT TO SCALE)

SECT.

VII

PAGE 

32

0707

Litho in U.S.A.

H

C1

C1

D

D

C2

H C2

GAS FLUE

28.31"

719mm

2.03"

52mm

5.00"
127mm

19.00"

482mm

3.50"

89mm

24.00"

610mm

25.88"

657mm

29.56"

751mm

37.00"

940mm

3.00"
76mm

6.12"
155mm

6.68"

170mm

29.65"

753mm

30.81"

782mm

35.43"

900mm

5.38"

137mm

1.38"

35mm

6.00"

152mm

7.50"

191mm

9.00"

229mm

12.50"

318mm

30.00"

762mm

62.00"

1575mm

32.21"

818mm

1.61"

41mm

1.61"

41mm

I.D.

15.75"

400mm

17.00"

432mm

WATER QUALITY 

REQUIREMENT

The recommended minimum water quality
standards whether untreated or pre-
treated, based upon 10 hours of use per
day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for
an on site water analysis for recommenda-
tions concerning steam generator feed water
treatment (if required), in order to remove or
reduce harmful concentrations of minerals.
The use of highly mineralized water will
mean that more frequent servicing of the
steam generator will be necessary. The fact
that a water supply is potable is not proof
that it will be suitable for the generator.

GAS

NATURAL

3/4" IPS for 200,000 

1.00" IPS for 300,000

Supply Pressure

4.00" W.C. Minimum

14.00" W.C. Maximum

PROPANE

3/4" IPS for 200,000

1.00" IPS for 300,000

Supply Pressure 

12.00" W.C. Minimum

14.00" W.C. Maximum

ELECTRIC

50 watts for generator

115 V-1 PH

WATER

C1: 1/4" IPS Cold water for boiler

C2: 3/8" NPT Cold water for faucet

C2: 3/8" NPT Hot water for faucet

DRAIN

1 1/2" IPS Common Drain

The floor drain must be 
located outside the confines 
of the equipment.

Do not connect to any other drain.

CLEARANCES

Right: 6.00"

Left:

6.00"

Rear: 6.00"

H

D

C1 C2

H

D

C1 C2

H

D

C1 C2

H

D

C1 C2

CAPACITIES

:

(in 4 oz. servings,

other sizes may be calculated.)

10 Gallon / 36 liters  . . . . . . .320 servings