
KW
280V 220V 240V 480V
24
3 PHASE
57
63
52
26
1 PHASE
99
N/A
89
45
36
3 PHASE
100
80
87
44
48
3 PHASE
119
127
107
53
ELECTRIC
WATER
DRAINAGE
CLEARANCE
C
D
1
⁄
4
" NPT cold water inlet
3
⁄
8
" NPT hot and
cold water for kettles
35 psi minimum
60 psi maximum
1
1
⁄
2
" IPS common drain
The Floor Drain must be
located outside the
confines of the
equipment base.
Do not connect any
other units to this drain.
RIGHT = 4.00"
LEFT = 0.00"
REAR = 0.00"
Allow 6.00" minimum
from rear and sides
when located near
combustible walls.
H
C
C
H
AMPS
PER
LINE
NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, CSA and NSF.
(NOT TO SCALE)
SECT.
VII
PAGE
38
0707
Litho in U.S.A.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated,
based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations
concerning steam generator feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of highly mineralized water will mean
that more frequent servicing of the steam generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable for the generator.