(NOT TO SCALE)

SECT.

III

PAGE 

16

0707

Litho in U.S.A.

1 1/2” IPS common drain.
Do not connect other units to
this drain.
Do not use PVC pipe for drain.

Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
acess)

Contact factory for 
variances to clearances.

NOTES

:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, /NSF and CSA.

Each compartment has capacity for:
Three, 12˝ x 20˝ x 2

1

2

˝ or six, 12˝ x 20˝ x 1˝ deep  

Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality 
standards whether untreated or pre-treated, based
upon 10 hours of use per day, and a Daily
Blowdown, are as follows:

TOTAL DISSOLVED 
SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on
site water analysis for recommendations concerning
steam generator feed water treatment (if required),
in order to remove or reduce harmful concentrations
of minerals. The use of highly mineralized water
will mean that more frequent servicing of the steam
generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable
for the generator.