Cleveland 24-GM-200 Скачать руководство пользователя страница 2

1 1/2” IPS common drain.

Do not connect other
units to this drain.

Do not use PVC pipe for
drain.

NOTES

:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and CSA (AGA, CGA).

(NOT TO SCALE)

SECT.

VII

PAGE 

4

0707

Litho in U.S.A.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more 
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it
will be suitable for the generator.

Right - 6”, Left - 6”, Rear - 6”

(12” on control side if adjoining
wall or equipment is over 30”
high for service access)

For use in non-combustible 
locations.

Contact factory for 
variances to clearances.

5.0 Amps

Отзывы: