
1 1/2” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC, UL/NSF#4 and CSA.
(NOT TO SCALE)
SECT.
VII
PAGE
36
0707
Litho in U.S.A.
CAPACITIES
(in 4 oz. servings)
(Other sizes may be calculated.)
6 gallon / 23 liters ..... 160 per kettle
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated,
based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations
concerning steam generator feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of highly mineralized water will mean
that more frequent servicing of the steam generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable for the generator.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment is
over 30” high for service
access)
Contact factory for
variances to clearances.