![Cleode ZigBee ZPILOT Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/cleode/zigbee-zpilot/zigbee-zpilot_user-manual_2622563009.webp)
Command of electric heater by wire pilot ZigBee™ – User Manual
UM_ZPILOT_20120903_001_01_00
CLEODE Page 9 sur 17
Cluster Scenes:
This cluster allows managing the scenes of which are a part the ZPILOT.
Attribute
Attribute ID
SceneCount
0x0000
CurrentScene
0x0001
CurrentGroup
0x0002
SceneValid
0x0003
NameSupport
0x0004
On/Off cluster:
This cluster is used to switching the device between ON and OFF states.
Attribute
Attribute ID
On/Off
0x0000
When this attribute value is ON, the last used mode is emitted on the wire pilot. The value
OFF emits the mode OFF on the wire pilot.
Pilot Control :
This cluster is used to change the mode on the wire pilot.
Attribute
Attribute ID
Mode
0x0000
The attribute Mode allows to know the order emitted on the wire pilot.
This cluster is a cluster owner to the company CLEODE. To modify this value, the
writing must be made by using to manufacture code CLEODE = 0x10B9.
The attribute Mode can take the following values:
Mode
Values
Comfort
0x00
Comfort – 1°C
0x01
Comfort – 2°C
0x02
Economic
0x03
Frost protection
0x04
OFF
0x05