Installation Guide_PV-ezRack SolarBalcony V1.0 (November 2020)  

04

page

 

of 06

Clenergy China 

999-1009 Min'an Rd, Huoju Hi-tech Ind. Dev. Zone 
Xiang'an District 361101, Xiamen, Fujian, China 

T

+86 592 311 0088

F

+86 592 599 5028

E

[email protected]

4.1.1 Check whether the modules, components 
and tools are ready. 

4.1.2 Adjust the connecting hole of U-Rail and 
C-Rail base on the installation angle. Do not 
fasten the bolt, keep the U-Rail rotatable as 
shown in Figure 1

Note: If necessary, use ribbons or other ropes 
to keep the U-Rail from falling after adjustment.

4.1.3 Fix the PV module and bracket with 
M6*20 screw (two plain washer, one washer, 
nut and screw), fasten the screws from top to 
bottom after position is determined, as shown 
in Figure 2.

Recommended torque for M6 bolts is 8~10 
N·m

Installation Instruction

Figure 2

4. Installation Instruction
4.1 PV Module Installation

Adjust the connecting 
hole of U-Rail base on 
the install angle

Figure 1

Содержание PV-ezRack Elevate Series

Страница 1: ...Elevate Series SolarBalcony Solar PV Mounting frame for high rise installations Want to grow energy on your Balcony...

Страница 2: ...cient strength and shear force Keep the roof waterproof system intact Recycling Recycle according to the local relative statute Removal Reverse installation process Ensuring that there are no less tha...

Страница 3: ...9 Min an Rd Huoju Hi tech Ind Dev Zone Xiang an District 361101 Xiamen Fujian China T 86 592 311 0088 F 86 592 599 5028 E sales clenergy com cn 2 1 Installation Tools 2 Tools Components 2 2 Components...

Страница 4: ...rofessional tools and tool belts are recommended 4 In some cases fasteners could be seized over time As an option if want to avoid galling or seizing of thread apply lubricant grease or 40 engine oil...

Страница 5: ...installation angle Do not fasten the bolt keep the U Rail rotatable as shown in Figure 1 Note If necessary use ribbons or other ropes to keep the U Rail from falling after adjustment 4 1 3 Fix the PV...

Страница 6: ...t and local safety regulations 4 2 2 Attach the upper bracket to the balcony with M8 125 bolt one plain washer washer nut and bolt Do not fasten the bolt as shown in Figure 3 4 2 3 Unfold the U Rail t...

Страница 7: ...ck SolarBalcony V1 0 November 2020 06 page of 06 Clenergy China 999 1009 Min an Rd Huoju Hi tech Ind Dev Zone Xiang an District 361101 Xiamen Fujian China T 86 592 311 0088 F 86 592 599 5028 E sales c...

Страница 8: ...ashita cho Yokohama 231 0023 Japan Tel 81 45 228 8226 Fax 81 45 228 8316 E mail sales clenergy co jp www clenergy jp Clenergy Philippines 145 Yakal St San Antonio village Makati City Philippines Tel 6...

Отзывы: