![Clena AGCL520 CL Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/clena/agcl520-cl/agcl520-cl_operation-assembly-safety-notes_2622509012.webp)
CLENA Nederland – www.clena.nl
pag. 12
Replace the Swivel O-Rings
1.
Disconnect the hose connection from the top of the swivel piping.
2.
Remove the swivel piping from the swivel fixture in the housing.
3.
Remove the bottom piece of the swivel as shown below.
4.
Replace the O-rings with replacement from the Easy Repair Kit.
5.
Reinstall the bottom piece in the swivel piping.
6.
Reinstall the swivel piping in the housing fixture.
7.
Reconnect the hose to the swivel piping.
Troubleshooting
Please check the list below before addressing the problems to servicing personnel including the local
dealer. If the problem continues after the following troubleshooting, please call your local dealer for
future assistance.
problem
possible cause
solution
nozzle blocked (not spraying)
dirty nozzle
twist the nozzle off and clean by
needle or paperclip
both nozzles are not spraying
dirty filter
clean or replace filter (see
maintenance section)
spray outward from sealing lip damaged sealing lip
replace the sealing lip
caster won’t roll or swivel
dirt in caster
clean the caster
Technical Specifications
WW
TC 301 CL
TC301 CL
TC 420 CL Industrial
TC 520 CL
AGCL
TC 520 CL
AGCL
TC 800 CL
Cleaning width
12.5 in
12 in
16 in
20 in
20 in
32 in
Max. pressure
3,000 PSI
3,600 PSI
3,600 PSI
4,000 PSI
5,000 PSI
5,000 PSI
Max. flow
3.5 GPM
4 GPM
5 GPM
6 GPM
6 GPM
8 GPM
Optional
HD gun
and lance
HD gun
and lance
Material
Stainless-steel
Max. temperature
200 °F
Weight
6 lbs.
7.7 lbs.
15 lbs.
36 lbs.
57 lbs.
66 lbs.