3 Scope of manual
These operating instructions apply to the following cabinet types. Please also note the operating instructions
for the components used.
Part no.:
Designation of the
cabinet
Components
Blast machine
(pot)
Pressure cyclone
Filter
12611Z
BNP 65 DS
SC 2040
900 CFM (25,4 m³/min)
MBX 1500
12613Z
BNP 220 DS
SC 2040
900 CFM (25,4 m³/min)
MBX 1500
100401
BNP 601 DS
SC 2040
900 CFM (25,4 m³/min)
MBX 1500
100412
BNP 721 DS
SC 2040
900 CFM (25,4 m³/min)
MBX 1500
100749
BNP 721 DS
SC 2040
900 CFM (25,4 m³/min)
MBX 2000
Option
BNP 75 / BNP 85
4 Product description
4.1 Conventional utilization and restrictions
BNP 65 / 75
BNP 220 / 85
BNP 601
BNP 721
Max. loading rate of the grate
/floor
1000 N
100 kp
1000 N
100 kp
2500 N
250 kp
2500 N
250 kp
Max. loading rate of the housing
2000 N
200 kp
2000 N
200 kp
10 000 N
1000 kp
10 000 N
1000 kp
Max. load rating with rack
(standard )
2000 N
200 kp
2000 N
200 kp
2500 N
250 kp
2500 N
250 kp
Operating time
Continuous duty
Basic parameters
See attached yellow cover
4.2 No conventional utilisation – Warnings for misuse
Utilization is interdicted:
As a blow –off cabinet in use of explosive and /or harmful solvents
-
in explosion hazard zones
-
for blasting parts, where hazardous materials were released
o
by explosion hazards
o
which where not retained enough by the dust collector
o
which causes damages caused to somebodys health during a defectuous dust collector