THEORY OF OPERATION/PRODUCT DESCRIPTION           CHAPTER 1

 

ClearWater  Tech  ozone  systems  are  designed  for  safe,  effective  use  in  a  variety  of  water  treatment  applications.  The 
SC27P ozone generator have been tested and certified by the Water Quality Association according to NSF/ANSI 50. Each 
complete, integrated system may include the following components required for reliable, efficient ozone production and 
can be divided into four general segments: 

 • Air preparation system   • Ozone generator   • Ozone injection/contacting   • Ozone destruct

  

 
 
 
 
 

 

 

 

 

 

 

 

Air Preparation System 

The ClearWater Tech  SC27P ozone generator requires a source of clean, dry, oil-free, oxygen-enriched air for effective 
ozone  production.  To  meet  that  need,  the  built-in  air  preparation  system  employs  pressure  swing  adsorption  (PSA) 
technology  with  an  oil-less  compressor  to  increase  the  concentration  of  oxygen  and  reduce  the  moisture  content  in  the 
feed gas (the air supplied to the ozone generator). This substantially improves the output capability of the ozone generator 
and  prevents  premature  failure  of  key  internal  components.  These  air  preparation  systems  deliver  90%+/-3%  oxygen 
purity at -100°F dew point and at very low pneumatic pressures, minimizing noise and reducing compressor wear. 
 
The  air  preparation  system  affects  ozone  production  in  grams  per  hour  and  more  importantly  ozone  concentration,  also 
known  as  “percent  by  weight.”  Since  ozone  is  produced  with  oxygen,  the  greater  the  percent  of  oxygen  that  enters  the 
ozone generator will produce more grams per hour and concentration of ozone.  Since the SC27P ozone generation system 
incorporates PSA oxygen concentrator it will yield the highest grams per hour at the highest concentrations. Greater ozone 
concentration equates to higher solubility of the ozone gas in solution, which will yield a greater oxidation potential.

Ozone Generator 

The  ClearWater  Tech  SC27P  self-contained  pressurized  ozone  generator  is  designed  to  supply  high  concentrations  of 
ozone gas (up to 10%) at 10 PSI.  The oxygen  feed gas produced by the  air preparation system is supplied to the ozone 
generator, which flows through the built-in flow meter. A stainless steel needle valve (located under the SC27P), is used 
to maintain optimum pneumatic parameters inside the ozone reaction chambers. After this point the vacuum created at the 
ozone  injector 

draws

  the  ozone  gas  into  the  water  line.  The  ozone  generator  is  equipped  with  a  pressure  switch,  which 

prevents operation if pressure within the reaction chambers drops below 9 PSI. 
 
As the feed gas  enters the fused, thermally protected reaction chambers inside the ozone generator, some of  the oxygen 
molecules  are  split  while  passing  through  the  high  voltage  electrical  field  (the  “corona”),  forming  single  oxygen  atoms 
(O

1

).  These oxygen atoms then recombine  with other  oxygen molecules in the air stream,  forming ozone.  The modular, 

multiple  reaction  chamber  design  allows  the  ozone  generator  to  keep  working  even  if  one  of  the  chambers  requires 
service. Depending on the application, the ClearWater Tech ozone generator may be interlocked with an ORP controller, 
PPM controller, pressure switch, timer or circulation pump. 

 

  Booster Pump   Ozone Injector 

 

 

Water Flow  

Off Gas  

      

  Vent                

 Optional Destruct System 

           Ozone Generator 

      Ozone 

                             Destruct  
                                Unit 

       
    
 

 

 

 

 

 

 

 

 

 
 

  Water Trap 

 

  

 

Shown: ClearWater Tech SC27P Ozone System

                      Contact Vessel 

 

Содержание SC27P

Страница 1: ...component only Tested and certified by WQA to NSF ANSI 50 as a component only ClearWater Tech LLC Integrated Ozone Systems 850 E Capitolio Way San Luis Obispo Ca 93401 805 549 9724 Fax 805 549 0306 E mail service cwtozone com www cwtozone com Copyright 2005 ClearWater Tech LLC Reproduction of any kind is prohibited LIT135 REV093010 ...

Страница 2: ...7P ozone generation system incorporates PSA oxygen concentrator it will yield the highest grams per hour at the highest concentrations Greater ozone concentration equates to higher solubility of the ozone gas in solution which will yield a greater oxidation potential Ozone Generator The ClearWater Tech SC27P self contained pressurized ozone generator is designed to supply high concentrations of oz...

Страница 3: ...ace area to the amount of ozone entering the water Depending on the application and the water treatment goals a ClearWater Tech contacting system may also be required Some oxidation reactions take place so quickly that they are limited only by the rate at which the ozone is dissolved in the water Other reactions such as disinfection may require that proper ozone residual be maintained for a specif...

Страница 4: ...is detectable at very low concentrations 0 02 ppm which is far below OSHA s maximum permissible exposure level of 0 1 ppm HIGH VOLTAGE WARNING CLEARWATER TECH OZONE GENERATORS OPERATE AT HIGH VOLTAGE DO NOT TAMPER WITH OR DELIBERATELY BYPASS THE COVER OR SAFETY SWITCHES BUILT INTO THE OZONE GENERATOR UNLESS INSTRUCTED TO DO SO BY THIS MANUAL IF CONTACT IS MADE WITH OPERATING HIGH VOLTAGE COMPONENT...

Страница 5: ...uipment 7 The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section 422 20 of the National Electrical Code ANSI NFPA 70 1987 The disconnecting means must be readily accessible to the operator s but installed at least five feet from any open body of water 8 Be sure to bond ground the system using th...

Страница 6: ...if so equipped In a Full Flow plumbing configuration see Figure 4 2 without recirculation locate downstream of the pH adjustment chemical injection point Adequate protection from weather dust and excessive heat Like any electronic component performance and longevity is enhanced by favorable operating conditions Also since ozone generator is air cooled a relatively dust free well ventilated area is...

Страница 7: ...nical print or as dictated by equipment layout and serviceability considerations Do not secure booster pump and contact vessel to housekeeping pads at this point Dry fit plumbing as appropriate to insure proper fit and location before making permanent connections Step 2 Install a tee or plumbing saddle into the main water line after the filter if so equipped and before the flow diversion mechanism...

Страница 8: ...the two holes for mounting the L bracket to the wall The bracket should be located so that the 6 clamp assembly will be approximately 12 from the top of the contact column Drill a 1 2 hole at each of the marks about 3 1 2 deep Insert a concrete anchor into each hole with the threaded end facing outward Slip the L bracket over the threaded ends of the anchors followed by a washer for each anchor Se...

Страница 9: ... Base Flange Gasket Base Flange Nuts Washers 8ea Contact Column Exploded View Figure 4 4 Contact Column Installation Diagram Figure 4 3 6 Clamp Assembly Bolts nuts with bolt Nut washers 2ea Unistrut cut to length Unistrut L Bracket Protective End cap Concrete Anchors with nuts washers 2ea ...

Страница 10: ...e output voltage will be 120VAC 2 amp max for a 120VAC 60Hz system or 220VAC 2 amp max for a 220VAC 50Hz system Using a 18 AWG wire from the External Contactor terminal 3 of the Electrical Hook up Box Terminal Strip to the coil side of a contactor If so required an External Contactor Neutral may also be wired using a 18 AWG wire from the Auxiliary Neutral terminal 5 to the coil side of the contact...

Страница 11: ...input signal and override the setting of the manual ozone output control Based on the 4 20mA signal ozone output will increase or decrease 4mA 0 ozone output 20mA 100 ozone output The Ozone Output is indicated by the LED s on the control panel of the ozone generator see Start Up and Calibration Procedures Figure 7 1A for LED function and Appendix Section A for LED location Note If the remote 4 20m...

Страница 12: ... Electrical Interface Figure 5 2 120V COIL N Power from ORP PPM pump or timer L1 Interface Relay External Loop 120VAC Signal 240VAC Signal L1 L2 240V COIL Interface Relay Power from ORP PPM pump or timer External Loop ...

Страница 13: ...generator and out to drain protecting the SC27P from potential water damage All pneumatic connections have been made between the ozone generation components of the SC27P and the vacuum break The only pneumatic field connections required are between the vacuum break ozone outlet fitting and the injector manifold Follow the steps outlined below for this procedure see Figure 6 2 Step 1 Remove the vac...

Страница 14: ... a ClearWater Tech vacuum test assembly to check vacuum at the injector port If no suction is present continue to close the ball valve on the injector manifold until vacuum is detected If using the vacuum test assembly check the VAC PSI gauge for vacuum If the needle is in the red zone on the pressure PSI side of the gauge gradually close the ball valve on the injector manifold until the needle mo...

Страница 15: ...y through it when the LED is not illuminated which indicates ozone is being produced The External Loop does not have continuity when the LED is illuminated which indicates no ozone production Manual Control Ozone output is being controlled by the Manual Ozone Output Control when LED is illuminated Remote 4 20mA Control Ozone output is being controlled by an External 4 20mA Control signal when LED ...

Страница 16: ...the drive module is in fault mode ozone will not be generated SC27P Drive Board Figure 7 1C Vacuum Break Check the water level in the vacuum break making sure it is above the flapper valve see Figure 6 2 If water is not pressing downward on the flapper valve it will open causing a loss of vacuum A loss of vacuum means ozone cannot flow from the vacuum break which in turn can cause an ozone leak No...

Страница 17: ...g steps outlined in the Start Up Calibration section Pressure Check the PSI gauge located on the ozone generator cabinet door Make sure pressure is within the range shown on the PSI Gauge line of the Pneumatic Operating Parameters chart see Figure 7 2 Adjust if necessary by following steps outlined in the Start Up Calibration section Vacuum Break Water Level Check the water level in the vacuum bre...

Страница 18: ...ter elements as required Note Fan filter stainless steel cover must be removed to access fan filters Depressurization Valve Rebuild the depressurization valve see Appendix Section A for location Check Valve Replace check valve located behind the system control panel see Appendix Section A for location Reaction Chambers Remove and disassemble one reaction chamber according to the steps outlined bel...

Страница 19: ... screw bosses until heads are snug against the end cap Step 5 Roll the high voltage anode foil like material lengthwise preserving the longer dimension Insert the rolled anode into the dielectric Center the anode in the dielectric approximately 1 2 from either end of the glass making sure it is rolled squarely Step 6 Slide the dielectric into the heat sink cathode assembly Seat the dielectric into...

Страница 20: ...or some water to be flowing from the injector during this procedure Contact Vessel Cleaning Contact Column only Inspect the diffuser slots at the top of the contact column riser tube If they are clear no further maintenance is required If the slots are fouled disassemble the column and clean as required following the steps outlined below see Figure 4 4 Step 1 Make sure the isolation valves before ...

Страница 21: ...uit breaker trips Incorrect wiring See Installation Procedures Electrical Circuit breaker amperage does not match draw Replace with correct circuit breaker Unit flooded with water Assess damage correct cause and rebuild as required Receive an electrical shock Incorrect wiring See Installation Procedures Electrical upon touching the unit Unit not grounded Ground unit according to local codes Unit f...

Страница 22: ...rt or debris in the ozone reaction Clean dielectric and replace O rings chamber Loose or disconnected High Voltage lead to Attach High Voltage lead to transformer transformer High temp limit If the temperature with in the SC27P system is greater than 150 F the drive modules will go to Fault mode Drive Module Main Power No power to drive module from Check main power to unit Green LED s not illumina...

Страница 23: ...valve check valve Water bubbling in vacuum No vacuum See Start Up Calibration break Debris on seat of vacuum break Clean seat of flapper flapper valve See Maintenance Procedures Annual Low vacuum at injector Hydraulics Pneumatics out of See Start Up Calibration adjustment Defective check valve Replace check valve Hydraulic back pressure Back wash filter if so equipped Check for obstruction in vent...

Страница 24: ... GENERATOR SPECIFICATIONS OZONE OUTPUT SCFH SC27P 34 h x 29 w x 13 d 139 lbs 27g h 6 12 scfh 10PSI Mounting Bracket Hole Measurement 16 w On Center Control Panel Access Door Control Panel Vacuum Break Cover Electrical Hook Up Cooling Fans Bonding Grounding Lug Stainless Steel Needle Valve Conduit Knockouts ...

Страница 25: ...ontrol Panel Oxygen Concentrator Compressor Compressor Cooling Coil Reaction Chamber Drive Module Oxygen Concentrator Sieve Bed ATF Vacuum Break Ozone Destruct and Depressurization Valve Compressor Inlet Filter Compressor Pressure Relief Valve Power Supply Main Power Fuse F1 Motor Controlled Interlock MCI Fuse F2 External Contactor Fuse F3 Terminal Strip 1 16 Exhaust Fans ...

Страница 26: ...ix continued 25 Section A Specifications SC27P Control Panel Shown ClearWater Tech SC27P Control Panel Front View Shown ClearWater Tech SC27P Control Panel Back View Pressure Switch Display Board Check Valve ...

Страница 27: ...Fuse Bussmann FNM 2 2 amp 250VAC Midget Time Delay External Contactor FUSE102 Fuse Littelfuse Minifuse 297003 3 amp 32VAC Drive Board FUS66 Maintenance Kit ASP500A Part QTY Description OXS350 1 Oxygen Concentrator Replacement Compressor Inlet Filter OXS356 1 Oxygen Concentrator Compressor Rebuild Kit OXS361 1 Oxygen Concentrator Compressor Pressure Relief Valve FA40 2 Filter Fan filter element onl...

Страница 28: ...27 APPENDIX Section C Logic Schematic Shown Electrical Schematic SC27P Line Side Note This system is not dual voltage rated System voltage is 120VAC 60Hz or 220VAC 50Hz ...

Страница 29: ...28 APPENDIX Section D Drive Module Input Voltages Shown HO Drive Module ...

Страница 30: ...enced with the product and or part must be clearly described The RGA number must appear prominently on the exterior of the shipped box es The product and or part must be packaged either in its original packing material or in comparable and suitable packing material if the original is not available You are responsible for paying shipping charges to CWT and for any damages to the product and or part...

Отзывы: