Compare the ozone system equipment to packing list provided. Before beginning any 

installation procedures, thoroughly inspect all components for damage. If damage is noticed, 

promptly notify the freight carrier and request an on site inspection. Inspect all packing 

materials for small parts before discarding.

•   When placing ozone system components, make sure to consider safety, maintenance

  requirements, local building and fire codes.  

•  To determine the most favorable placement, the following should be considered:

   •  Located downstream of all other existing water system components.

   •  Located upstream of the residual sanitizer injection point (if so equipped).

   •  The pH adjustment chemical injection point should be located downstream of the       

   residual sanitizer injection point (if so equipped).

   •  Location of ozone generator should be no more than 8 feet from point of use.

   •  Adequate protection from weather, dust and excessive heat. Ambient temperature     

   range: 20ºF to 85º F continuous.

nOTe:

 Equipment installed in extreme environmental conditions will void manufacturers warranty.

•  The ozone generator is equipped with a 0 to 100% variable OFF/ON switch. Depending

  on the amount of ozone required you may adjust the ozone output control switch 

  counter clockwise for minimum output or off and clockwise for maximum output.
•  The ozone generator is equipped with a main power indicating light next to the variable

  switch. This light will be illuminated when the switch is not in the off position. 
•  The ozone generator will not produce ozone until airflow is initiated.

Disconnect power from unit before any maintenance procedures.

  •  Check valve – replace diaphragm check valve, annually.

  •  Reaction chamber - replace the reaction chamber every 3 years.

Microzone 300  

  •  Electrical – 120VAC  60Hz 0.2A, 220VAC 50Hz 0.1A

  •  Dimensions – 5.875" h x 5.375" w x ” x 2" d, 2 lbs.

  •  Ozone Output – 0.3 g/h @ 6 SCFH

Microzone 500

  

  •  Electrical – 120VAC  60Hz 0.4A, 220VAC 50Hz 0.2A

  •  Dimensions – 6.250” h x 9.375” w  x 3.5” d. 3 lbs.

  •  Ozone Output – 0.5 g/h @ 5 SCFH

 

5

2

UNPACKING

nOTe:

 The top of the Hartford loop and the check valve must be mounted above the water line

MAINTENANCE

SPECIFICATIONS

START-UP

EQUIPMENT PLACEMENT

The  microzone  ozone  generators  may 

be  used  to  inject  or  diffuse  ozone 

into  water.  The  injection  method 

requires  a  venturi  injector  to  draw  the 

ozone  from  the  ozone  generator  and 

into  the  water  line.  ClearWater  Tech 

has  developed  the  PRO  Series  Sys

-

tem  with magnetic drive pump, program

-

mable  timer  and  venturi  to  provide  a 

suitable  suction  port  for  the  injection 

method  (see  Figure  1).  For  typical  spa 

applications  the  spa  manufacture  has 

provided an “ozone ready” suction port, 

which eliminates the need for additional 

equipment  (see  spa  manual  for 

installation). The diffusion method requires 
a pressurized  air  source,  which  feeds  air 

       

  

through  the  ozone  generator  and  out  to 

an atmospheric body of water. A diffuser 

stone provided with the Microzone ozone 

generator is used for increased mixing 

of ozone in solution. For this applica

-

tion ClearWater Tech has developed the 

OAS7  compressor,  with  programmable 

timer to provide the  pressure required 

(see Figure 2). 

note: 

Regardless of application, water back flow 

prevention devices such  as a check valve 

and Hartford Loop should be implemented 

with  the  use  of  the  Microzone  ozone 

generators (see figure 3). 

THEORY OF OPERATION & PRODUCT DESCRIPTION

Figure 3

Shown: Hartford Loop

Check Valve

Coiled Tubing

Min. of three

12” loops

(Harford Loop)

To point of use

From ozone generator

Waterline

Содержание Microzone 300

Страница 1: ...ervice cwtozone com www cwtozone com Copyright 2008 ClearWater Tech LLC Reproduction of any kind is prohibited LIT94 REV111208 ClearWater Tech LLC Ozone Systems for Water Air Purification Ozone Systems Installation Operation Manual Microzone 300 500 Corona Discharge Ozone Generators ...

Страница 2: ...ot sold by CWT Service or unit modification not authorized by CWT Check valve solenoid valve failure Failure to meet service requirements as outlined in the I O manual Damage which may occur during shipping Obtaining Service Under the Warranty Any product and or part not performing satisfactorily may be returned to CWT for evaluation A Return Goods Authorization RGA number must first be obtained b...

Страница 3: ...gm check valve annually Reaction chamber replace the reaction chamber every 3 years Microzone 300 Electrical 120VAC 60Hz 0 2A 220VAC 50Hz 0 1A Dimensions 5 875 h x 5 375 w x x 2 d 2 lbs Ozone Output 0 3 g h 6 SCFH Microzone 500 Electrical 120VAC 60Hz 0 4A 220VAC 50Hz 0 2A Dimensions 6 250 h x 9 375 w x 3 5 d 3 lbs Ozone Output 0 5 g h 5 SCFH 5 2 UNPACKING Note The top of the Hartford loop and the ...

Страница 4: ...o a suitable flat surface using the two self tapping screws provided Note The distance from the Microzone to point of diffusion should be no more than 8 feet Step 2 Cut a suitable length of the supplied tubing attach one end to the air prep outlet of the pressurized source used Attach the other end to the air inlet port of the Microzone and secure with a hose clamp provided Step 3 Attach one end o...

Отзывы: