ClearWater CTA5 Скачать руководство пользователя страница 2

A

Installation

Dimension

2 - 2

To remove the cartridge.

First shut off the water supply to the tap.

1: Pull out the cap from the handle.
2: Loosen the grub screw in handle, but do not remove it. 
3: Take off the handle, unscrew the cartridge cover. 
4: Using a correct size spanner unscrew the retaining nut.
5: Pull the cartridge and wash it with clean running water.
6. Dry and lightly grease the seals (only use silicone grease) 
7: Replace them in turn.

MIXER BODY

CARTRIDGE

RETAINING
NUT

CARTRIDGE
COVER

HANDLE

ALLEN
KEY

GRUB 
SCREW

CAP

2-G3/4

197

108

Ø28

166

Ø55

Ø55

35

99

154

22

Max30

FLEXIBLE PIPES
LEFT:   HOT FEED
RIGHT: COLD FEED

FIXING NUT

HANDLE

NOZZLE

MIXER BODY

WASHER

1: Fit the washer into the groove in the underside of the mixer body.
2: Screw the flexible pipes into the mixer body, and fully hand tighten. 
3: Pass the tail of flexible pipes through the hole on the bath from above, and place the mixer in position on the bath, to see if any 
    alteration to the existing supply pipe work is necessary, make any necessary alterations to the pipe work. 
4: Slide the fixing nut up the tails and onto the fixing bolt.
5: Check that the mixer body is correctly positioned, fully tighten the fixing nut. 
6: Connect the water supply pipe to the tail of flexible pipes with the hot water on the left and cold water on the right. 
     