OPERATION
1. The pump must be submerged at all times during normal opera-
tion.
Do not run pump dry.
2. Make sure that the float switches are set so that the pump stops
before the pump runs dry or breaks suction. If necessary, adjust
float switches to achieve this.
3. The motor bearings are lubricated internally. No maintenance is
required or possible on the pump.
3
Table 1: Recommended Fusing Data
60 Hz/1 Phase 2-Wire Cable
Max
Locked
Fuse Size
Volts/Hz/
Load
Rotor
Standard/
Model
HP
Phase
Amps
Amps
Dual Element
P10D
1/2 115/60/1
11.0
30.0
15
P20D
1/2 115/60/1
9.5
30.0
15
P30D
1/2
115/60/1
9.5
30.0
15
T
otal Dynamic Head in Feet (M)
Flow in USGPM (LPM)
0
(0)
10
(38)
20
(76)
30
(114)
0(0)
150(46)
200(61)
250(76)
100(30)
50(15)
20 GPM
20 GPM+1
40
(151)
30 GPM
10 GPM
Submersible
Pump
3" to 4" Pipe
Adapter
4" Pipe
3" Pipe
Figure 1: Insert a piece of 3" PVC pipe in the bottom of
the motor to raise the pump in the tank.
Figure 2: Performance in Feet of Head at Gallons Per
Minute (M@LPM).