background image

   OPERATING MANUAL

 

In  the  event  you  experience  a  problem  with  your  Clearstream  Aerobic  Wastewater Treatment 

System or if service is required, you may reference the Clearstream Control Panel Cover for the name, 
address  and  phone  number  of a local  service person  that can provide  service for your  Clearstream 
Unit. After the expiration of  your  initial two  year service policy  provided  by  the system installer, you 
may obtain a continuing  service policy  on a yearly basis which  will include  terms comparable  to the 
initial service policy from a local service person that is trained and certified by Clearstream. 

In order  for the Clearstream System to function  at optimum  performance  levels, the system will 

require periodic  service. The normally expected service that is associated with the system includes: 

1.

Repair or replace aerator

2.

Clean filters on aerator

3.

Break up scum in clarifier

4.

Pump sludge from aeration tank

5.

Pump sludge from pretreatment tank

6.

Check aeration diffusers

7.

Check surge control weir

8.

Check denite effluent return flow

9.

Replace UV bulb

 (when UV is installed)

2 to 10 years 
6 mos. to 2 years 
6 mos. to 2 years 
2 to 5 years* 
2 to 5 years* 
annually 
6 mos. 
6 mos. 

annually 

* Any sludge removed from pretreatment tank or Clearstream Unit must be disposed  of according  to all state, local and federal

regulatory requirements.

To remove solids from pretreatment tank drop pump hose through access opening on top of tank 

all the way through to the bottom of the tank. Pump out the whole tank volume, then fill the tank back 
up immediately. To remove solids from aeration chamber, drop hose through  access opening  in tank 
all the way to the bottom  of the tank. Pump only 1/2 of the total tank volume and fill tank back up with 
water immediately. 

To determine  if all system  components  are functioning  properly,  look  and/or  listen  to  see if the 

visual/audio  alarm  system  is  illuminated  or  making  a buzzing  sound.  If the  alarm  is  activated,  then 
either the  aerator has lost air pressure  or  the  high  level float  inside  the  clarifier is  indicating  a high 
water  level  condition.  Verification  of  either  condition  can  be  made  by  checking air pressure from 
aerator with a pressure gauge  and  opening  the  access opening  to  the  treatment  unit  to  see  if  the 
water  level inside  the  clarifier is  at  alarm  level. After inspection  of  the  clarifier,  be  sure  to 
securely fasten the access cover back  in place and tighten  the tamper resistant 

screws

 firmly. 

To  determine  if  the  system  has  the  desirable  “mixed  liquor” and  effluent  characteristics, first 

remove the access cover. Monitor  for odors  coming  from the tank. If the odor  is a sweet or a musty 
smell, the system  is operating in a  desirable aerobic condition.  If the odor is foul or smells like a 
rotten egg,  then the system is operating  in an undesirable  anaerobic  condition.  Visually monitor  the 
“mixed liquor”  for color.  If the color  is a  brownish  color,  then it is operating  in a  desirable aerobic 
condition. If it is grey or black in color,  it is operating in an undesirable anaerobic condition.  The 
system effluent should  be  clear  with  very few noticeable  light  brown  solids  suspended  in  the 
effluent. The effluent should  not  be  dark  or  turbid  in  color  or  clear  with  great  numbers  of  light 
brown  suspended  solids noticeable. After inspection  of the system’s  interior,  be sure to securely 
fasten the access cover back in place and tighten the tamper resistant 

screws 

firmly. 

In  the  event  the  alarm  panel  light  and  buzzer  is  activated,  call  your  local  servicing  dealer 

whose name, address, and phone number should be affixed to the face of the panel. 

3

 of 1

2

Содержание 600DAT

Страница 1: ... 1500 Fax 409 755 6500 www clearstreamsystems com OWNER S MANUAL PARTS LIST OPERATING MANUAL FLOW DIAGRAM INSTALLATION INSTRUCTIONS DESIGN DRAWINGS AND SPECIFICATIONS SERVICE POLICY LIMITED WARRANTY MODEL 600DAT NSF ANSI 40 Class I 245 350 1 of 12 ...

Страница 2: ...xed liquor The mixed liquor passes into the bottom of the clarifier by hydraulic displacement as wastewater enters the aeration chamber Solids settled from the wastewater are drawn back into the aeration chamber from the bottom of the cone by the hydraulic roll created by the air released in the aeration chamber and are dispersed by the mixing induced by the aerator An airlift assembly controlled ...

Страница 3: ...l tank volume and fill tank back up with water immediately To determine if all system components are functioning properly look and or listen to see if the visual audio alarm system is illuminated or making a buzzing sound If the alarm is activated then either the aerator has lost air pressure or the high level float inside the clarifier is indicating a high water level condition Verification of ei...

Страница 4: ...l be honored For the Clearstream Aerobic Wastewater Treatment Unit to function properly it must be used for the treatment of domestic wastewater from residences or other waste flows with similar loading characteristics Typical domestic wastewater consists of the flow from toilets lavatories sinks bathtubs showers and washing machines To prevent malfunctions of your Clearstream Unit the following g...

Страница 5: ...t distance If dropped hard enough the cast aluminum housing may be damaged and render the compressor useless 3 The most common issue resulting from a linear compressor being handled inappropriately is the safety switch being tripped Please refer to the repair manual for switch reset instructions if the compressor fails to power up 4 All control panels are packaged to prevent damage during shipping...

Страница 6: ...inlet 4 Sch 40 PVC pipe is aligned properly to incoming sewage line 5 For the Clearstream Unit to function properly the tank must be level To properly level the tank lay a three 3 foot level across the tank in several directions Shift the tank in the hole as necessary to make the tank level in all directions The tank may be slightly out of level but it should not be out of level enough to cause ta...

Страница 7: ...ompliance with NFPA 70 for all electrical components electrical connections and system installation 3 Install Clearstream Aerator Model CS 103ET6 as close as practical to the tank but in no case greater than one hundred 100 feet away Run 3 4 Sch 40 PVC air line from aerator connector to the air line connection at Clearstream tank Be careful to backfill under ground air line in manner which will no...

Страница 8: ...Intakelevel 600 G P D 1 5 lbs BOD 2 8 scfm Raintight 115v 60Hz 0 75 amps Plant Design Flow 100 of ATU Design Flow 30 Inches 6 inches below liquid 25 to 50 of liquid Inlet flow line must be a minimum of two inches higher than the outlet flow line 1of 12 8 of 12 Model 600DAT Treatment Capacity BOD Loading Aerator CS 103ET6 Control Panel Model CS 114 Electrical ...

Страница 9: ...LOW LIQUID LEVEL 4 4 OUTLET TEE BAFFLE INTAKE 25 TO 50 OF LIQUID DEPTH 5 INLET FLOW LINE MUST BE A MINIMUM OF 2 HIGHER THAN THE OUTLET FLOW LINE AIR LIFT ASSEMBLY CLARIFIER AERATION CHAMBER 88 CS 120UV optional for Std 40 and 245 applications Required for Std 350 applications 20 ACCESS COVER 12 ACCESS COVER HIGH LEVEL FLOAT SURGE FLOW CONTROL WEIR 3 4 S 40 PVC RECYCLE RETURN FLOW LINE AIRLIFT FLOW...

Страница 10: ...ERATOR POLYETHYLENE HOUSING 15 AIRLIFT RECYCLE ASSEMBLY 16 GAS BAFFLE 17 FLOW CONTROL WEIR 18 UV DISINFECTION DEVICE optional Std 40 245 req Std 350 PART NUMBER CS 101 CS 102 CS 103ET6 CS 107 CS 108 CS 109 CS 11 CS 113 CS 114 CS 116A CS 116 CS 130 CS 131 CS 106 CS 132 CS 117 CS 111 CS120UV COMPONENT PARTS MAY BE OBTAINED FROM YOUR LOCAL SERVICING DEALER OR PO BOX 705 BEAUMONT TX 77726 800 586 3656...

Страница 11: ...erves the right to revise change or modify the construction and design of the Clearstream Aerobic Treatment System or any component part or parts thereof without incurring any obligation to make such changes or modifications in equipment previously sold Clearstream also reserves the right in making replacements of component parts under this warranty to furnish a component which in its judgement is...

Страница 12: ...CLEARSTREAM WASTEWATER SYSTEMS INC P O Box 7568 Beaumont Texas 77726 7568 Phone 409 755 1500 Fax 409 755 6500 www clearstreamsystems com Copyright 7 01 2013 Revised 10 1 2020 12 of 12 ...

Отзывы: