      DESIGN DRAWING

CLEARSTREAM  600DAC3

SECTION

CLEARSTREAM

PLAN

CLARIFIER

DIFFUSER

EFFLUENT PUMP

PRETREATMENT

CONTROL  PANEL

FLOW  LINE

AIR  LINE

60"

58"

3" WALL  

151"

TANK

AERATION

TANK

TANK

PUMP

CONDUIT

SURGE  CONTROL

WEIR  AND  FILTER

4"  PVC  

82"

AIR LIFT  RETURN  3/4" PVC : MUST BE LYING ON CONCRETE - USE 45    TURNS

ACCESS COVER FOR 20" OPENING

154"

  INLET 

AIR LINE  3/4" PVC

20" ACCESS COVER

AIR SUPPLY DROP 3/4" PVC

6"

HIGH LEVEL ALARM FLOAT

AIRLIFT ASSEMBLY

AERATOR

AIRLIFT AIR SUPPLY

1" TREATED EFFLUENT DISCHARGE

GRADE

AERATOR

AIRLIFT SUPPLY LINE 

10"

AIRLIFT INLET

3/4" FLEX PIPE

3/4" FLEX PIPE

CS

UV1

 optional 

for Std 40 and 245 
applications.
Required for Std 350
applications.

20" ACCESS COVER

CS

UV1

 DISINFECTION

PUMP HEAD DISCHARGE ASSEMBLY

 

HIGH  LEVEL  ALARM  FLOAT

 

RETURN TO PRETREAT

12" ACCESS COVER 

CS103ET6 AERATOR

of 12

Содержание 600DAC3

Страница 1: ... 1500 Fax 409 755 6500 www clearstreamsystems com OWNER S MANUAL PARTS LIST OPERATING MANUAL FLOW DIAGRAM INSTALLATION INSTRUCTIONS DESIGN DRAWINGS AND SPECIFICATIONS SERVICE POLICY LIMITED WARRANTY MODEL 600DAC3 NSF ANSI 40 Class I 245 350 1 of 12 ...

Страница 2: ...the mixed liquor The mixed liquor passes into the bottom of the clarifier by hydraulic displacement as wastewater enters the aeration chamber Solids settled from the wastewater are drawn back into the aeration chamber from the bottom of the cone by the hydraulic roll created by the air released in the aeration chamber and are dispersed by the mixing induced by the aerator An airlift assembly contr...

Страница 3: ...ly To determine if all system components are functioning properly look and or listen to see if the visual audio alarm system is illuminated or making a buzzing sound If the alarm is activated then either the aerator has lost air pressure or the high level float inside the clarifier is indicating a high water level condition Verification of either condition can be made by checking air pressure from...

Страница 4: ...l be honored For the Clearstream Aerobic Wastewater Treatment Unit to function properly it must be used for the treatment of domestic wastewater from residences or other waste flows with similar loading characteristics Typical domestic wastewater consists of the flow from toilets lavatories sinks bathtubs showers and washing machines To prevent malfunctions of your Clearstream Unit the following g...

Страница 5: ...t distance If dropped hard enough the cast aluminum housing may be damaged and render the compressor useless 3 The most common issue resulting from a linear compressor being handled inappropriately is the safety switch being tripped Please refer to the repair manual for switch reset instructions if the compressor fails to power up 4 All control panels are packaged to prevent damage during shipping...

Страница 6: ...re the inlet 4 PVC pipe is aligned properly to incoming sewage line 5 For the Clearstream Unit to function properly the tank must be level To properly level the tank lay a three 3 foot level across the tank in several directions Shift the tank in the hole as necessary to make the tank level in all directions The tank may be slightly out of level but it should not be out of level enough to cause ta...

Страница 7: ...ompliance with NFPA 70 for all electrical components electrical connections and system installation 3 Install Clearstream Aerator Model CS 103ET6 as close as practical to the tank but in no case greater than one hundred 100 feet away Run 3 4 Sch 40 PVC air line from aerator connector to the air line connection at Clearstream tank Be careful to backfill under ground air line in manner which will no...

Страница 8: ...Intakelevel 600 G P D 1 5 lbs BOD 2 8 scfm Raintight 115v 60Hz 0 75 amps Plant Design Flow 100 of ATU Design Flow 30 Inches 6 inches below liquid 25 to 50 of liquid Inlet flow line must be a minimum of two inches higher than the outlet flow line 1of 12 8 of 12 Model 600DAC3 Treatment Capacity BOD Loading Aerator CS 103ET6 Control Panel Model CS 114 Electrical ...

Страница 9: ...E45 TURNS ACCESSCOVERFOR20 OPENING 154 INLET AIRLINE 3 4 PVC 20 ACCESSCOVER AIRSUPPLYDROP3 4 PVC 6 HIGHLEVELALARMFLOAT AIRLIFTASSEMBLY AERATOR AIRLIFTAIRSUPPLY 1 TREATEDEFFLUENTDISCHARGE GRADE AERATOR AIRLIFTSUPPLYLINE 10 AIRLIFTINLET 3 4 FLEXPIPE 3 4 FLEXPIPE CSUV1 optional for Std 40 and 245 applications Required for Std 350 applications 20 ACCESSCOVER CSUV1DISINFECTION PUMPHEADDISCHARGEASSEMBLY...

Страница 10: ...4 AERATOR POLYETHYLENE HOUSING 15 AIRLIFT RECYCLE ASSEMBLY 16 GAS BAFFLE 17 FLOW CONTROL WEIR 18 UV DISINFECTION DEVICE optional Std 40 245 req Std 350 PART NUMBER CS 101 CS 102 CS 103ET6 CS 107 CS 108 CS 109 CS 11 CS 113 CS 114 CS 116A CS 116 CS 130 CS 131 CS 106 CS 132 CS 117 CS 111 CSUV1 COMPONENT PARTS MAY BE OBTAINED FROM YOUR LOCAL SERVICING DEALER OR PO BOX 705 BEAUMONT TX 77726 800 586 365...

Страница 11: ...erves the right to revise change or modify the construction and design of the Clearstream Aerobic Treatment System or any component part or parts thereof without incurring any obligation to make such changes or modifications in equipment previously sold Clearstream also reserves the right in making replacements of component parts under this warranty to furnish a component which in its judgement is...

Страница 12: ...CLEARSTREAM WASTEWATER SYSTEMS INC P O Box 7568 Beaumont Texas 77726 7568 Phone 409 755 1500 Fax 409 755 6500 www clearstreamsystems com Copyright 7 01 2013 Revised 9 8 2021 12 of 12 ...