ClearSpan 3620CC Скачать руководство пользователя страница 7

Step 6:

 Check the rafter-to-rafter dimensions along all the purlins. Also check that every rafter is 

standing up straight (plumb). Square the corners by measuring diagonally corner-to-corner, and 
line up all rafters using a straight line.

          

  Section D - Installl Additional Bays

Step 1:

 Once you have the first bay installed and anchored, you can attach the second and any 

additional bays one at a time, a rafter at a time. Bays share a common center "Y" post.

  Section E - Finish Rough Edges

Step 1:

 Check for any sharp edges on the frame and file them smooth so they will not cut the cover.

Step 2:

 Apply two layers of heavy duct tape on all pipe connections and connectors that may 

contact the cover.

Page 7

Содержание 3620CC

Страница 1: ... SKU 3650CC 36 Wide x 50 Long SKU 3660CC 36 Wide x 60 Long SKU 5420CC 54 Wide x 20 Long SKU 5430CC 54 Wide x 30 Long SKU 5440CC 54 Wide x 40 Long SKU 5450CC 54 Wide x 50 Long SKU 5460CC 54 Wide x 60 Long 2004 ClearSpanTM All rights reserved Reproduction prohibited without written permission Rev 16 July 04 Note Photo may be of a different but similar model ...

Страница 2: ... tools Never erect a shelter directly under power lines Be careful not to drive anchors into buried power cables Do not climb on the shelter or its frame It is not designed to support human weight If the shelter is enclosed provide proper and adequate ventilation Do not store hazardous materials in the shelter without proper ventilation and precautions If both ends are covered provide proper ingre...

Страница 3: ...e shelter These could be pressure treated posts precast concrete blocks or poured in place footings Drainage is another important consideration Rain flowing off your shelter should have a natural path to flow away from the shelter and not under or into it Section A Unpack Identify Parts Step 1 Before you begin to assemble your shelter you should first unpack the contents of your shipment During th...

Страница 4: ...tification Note Illustrations are not to scale Page 4 3 8 Conduit only swaged is shown Tek Screw Driver Bit 3 Way Coupler 4 Way Coupler Strap Ratchet Cover Plain End Strap Cross Connector Rafter Section A Y Post ...

Страница 5: ...nd add sections to form a house shaped arch like the one below laying flat on the ground It is essential that you perform this step on level ground or the completed rafter assembly will be twisted 2 4 2 3 4 h v 2 4 2 3 4 h v h9v490 h9v490 84 3 84 3 2 4 2 3 4 h v 2 4 2 3 4 h v 50 2 2 33 4 2 2 33 4 2 Typical End Rafter Assembly Step 4 Repeat the steps above to assemble the other end rafter identical...

Страница 6: ...ontinue to provide support to both rafters to prevent them from falling down or twisting Step 3 Slide a swaged purlin through the cross connectors to connect these two rafters just above the Y pipes on one side The non swaged end must be flush with the connector on the end rafter Step 4 Repeat with another swaged purlin at the other side of these first two rafters You should now have a 2 rafter st...

Страница 7: ... Installl Additional Bays Step 1 Once you have the first bay installed and anchored you can attach the second and any additional bays one at a time a rafter at a time Bays share a common center Y post Section E Finish Rough Edges Step 1 Check for any sharp edges on the frame and file them smooth so they will not cut the cover Step 2 Apply two layers of heavy duct tape on all pipe connections and c...

Страница 8: ...ur shelter using several 75 swaged sections and 1 25 49 or 73 depending on your model unswaged section for each one Note Cover conduits are made from 1 315 O D pipe Step 3 Slide the cover conduits into the hem openings at the end of each side of the cover Step 4 To pull the cover over the frame attach ropes to both ends of the cover conduit Wrap the rope around the conduit a few times as shown bel...

Страница 9: ... with a Tek screw in the bottom hole of the ratchet There should be a few inches between the end of the cover and the ratchet Note Photo may be of a different but similar model Step 9 Cut off the excess strap leaving 12 in length Step 10 Feed the strap through the center slot in the ratchet and tighten slightly Step 11 On the sides of the shelter identify the legs where you will install side ratch...

Страница 10: ... leg where you installed a ratchet Cut a 2 long slit in the hem just above the cover conduit Repeat this step on the other side of the hem so you can pass a 1 wide strap over the conduit through the slits Side Strap Installation Step 14 Then slip straps through the slits so the strap goes around the cover conduit Feed the both strap ends together through the slot in the ratchet spool and tighten s...

Страница 11: ...e in identifying needed parts call us toll free at 1 888 603 4445 If shelter is moved after construction inspect shelter thoroughly before reuse Do not allow snow to accumulate on the cover Use a means of snow removal that will not cut or damage the cover Never attempt to climb on or stand on the shelter or its frame Note that ClearSpanTM shelters Truss Arch excepted do not have any tested loading...

Отзывы: