ClearPlus WH2-HF Скачать руководство пользователя страница 5

 

5.

 

Scrub the bottom of the housing and cap with dish soap and warm water using a sponge or 
soft cloth.  Fill 1/3 with water and add about 2 tablespoons of household bleach.  Scrub to 
disinfect (we recommend that you use rubber gloves).  

Rinse all parts thoroughly!

 

 
 

6.

 

Lubricate the O-ring with food-grade silicon lubricant if needed.  Insert O-ring in the 
groove at the top of the blue sump and press into place.  

Make sure the O-ring is 

seated level in the groove!

 

 
 

7.

 

Remove the protective plastic wrapping from the new filter cartridge and insert the 
cartridge into the housing sump, making sure that it slips over the standpipe in the bottom 
of the housing. 

 
 

8.

 

Screw the blue sump onto the black housing cap tighten using the spanner wrench

.  Do 

not over tighten.

   

 
 

9.

 

Turn on the water supply slowly to allow the system to fill with water.  Depress the red 
pressure release button on top of the unit again to release any trapped air.  

Inspect 

carefully for leaks.

  If a leak is found, first inspect the O-ring to ensure that it is seated 

properly before tightening the sump more.  Tighten using the spanner wrench as necessary 
to achieve a good seal and stop leaks. 

 
 

10.

 

New cartridges may release “fines” (very fine black powder) after installation.  Flush the 
system by running water from a nearby faucet for 5 minutes.  Wait one hour, and flush 
again for another 5 minutes prior to using the water. 

Содержание WH2-HF

Страница 1: ...water treatment applications This filter is followed by Pentek s EP Series 5 micron carbon block filter which features greater chlorine removal and dirt holding capacity than competitor s filters of a similar size The high porosity design helps prevent the cartridge from clogging before its absorption capacity is exhausted maximizing the utilization of the activated carbon media The carbon block f...

Страница 2: ... help drain the pipes STEP 3 Using a pipe cutter cut out a section of your main water line at the point where you want to install your filter system There will probably be some water remaining in the system so be sure to have a bucket and some rags handy to clean up any small spills Make sure that the section of water line you remove is appropriately sized such that all of the components of the sy...

Страница 3: ...ve force is not required to obtain a good seal STEP 6 Turn on the water and inspect all plumbing connections very carefully for leaks Also inspect the seal between the black housing caps and the blue housing sumps to ensure that the O ring has formed a good seal Tighten this connection again using the spanner wrench if necessary If this connection still leaks turn off the water supply and check to...

Страница 4: ... you of filter replacement schedules Replacement Filters Hydronix SDC 45 2010 replace every 6 12 months Pentek EP 20BB replace every 40 000 gallons 6 9 months Replacement Filters can be Obtained as Follows Phone Toll Free 1 866 376 2690 or Order Online at www home water purifiers and filters com Filter Cartridge Replacement Procedure 1 Turn off the water supply to the system using the shut off val...

Страница 5: ...e that it slips over the standpipe in the bottom of the housing 8 Screw the blue sump onto the black housing cap tighten using the spanner wrench Do not over tighten 9 Turn on the water supply slowly to allow the system to fill with water Depress the red pressure release button on top of the unit again to release any trapped air Inspect carefully for leaks If a leak is found first inspect the O ri...