CONVERGE PA 460 AND PA 4120 AMPLIFIERS
6
FRONT PANEL
STANDBY/PROT CLIP
INPUT
OUTPUT
POWER
POWER SWITCH
1.
STANDBY/PROT
This light indicates either Standby or Protection mode.
•
A solid orange light indicates that the amplifier is in Standby mode
(which occurs when Standby has been turned on and no signal has
been received for around a minute). Standby mode ends once an
audio signal is received.
•
A blinking orange light indicates that the amplifier is in Protection
mode. Protection mode can result from a speaker line short circuit, a
speaker line open circuit, amplifier overload, or an inner working tem-
perature over 131°F (55°C). When in Protection mode, the channel is
turned off (no audio signal is passed). The indicator light continues
to blink until the problem is resolved.
There are Standby/Prot indicators for each of the four channels.
2.
CLIP
Red clip indicator lights turn on when the input or output is too high.
There are Clip indicators for each of the four channels.