rial that supports the expander. Exercise care when you drill and install anchors so wall material does not tear out and
weaken the attachment.
Above The Ceiling
Select hardware based on your specific installation needs.
Note:
It is the installer’s responsibility to ensure that the installation and cable routing complies with local safety codes.
1. Determine location for the mount, and where to route cables.
Mark location where you want to route cables through with a
pencil (on finished side of ceiling tile) if you need to cut a hole.
2. Remove affected ceiling tile and adjacent tiles required for access.
3. Install fasteners/anchors.
4. Install expander unit at determined location.
5. Use drywall saw to cut hole into finished side of ceiling tile at marked location.
Note the following:
• Carefully run connected cables so they do not block the cooling vents or put strain on the connectors.
• Anchors and screws used to mount the expander are not provided and must be selected by installer for the type of
ceiling material supporting the expander. Take care while drilling and installing anchors so ceiling material does not
tear out and weaken attachment.
Figure 1. BMA CTH Back Panel
Step 3: Connect the Components
a. Description of Controls and Connections
Description
a
Speakers Out. Two Phoenix Euroblock connectors for external 8 ohm speakers
b
PoE In: RJ45 connector. The Versa Lite CT does not use this connector. The Versa USB provides power to the
BMA CTH through the P-Link In connector.
c
Power Select sliding switch. Position determines power source – either left for PoE In or right for P-Link In. With a
Versa Lite CT, this switch is set to the right for P-Link In.
d
P-Link In: RJ45 connector. Receives power, audio, and control from the Versa USB.
e
P-Link Out: RJ45 connector. Connects to another P-Link device that requires power, such as a Bluetooth Expand-
er.
BMA CTH
Warning:
Power over Ethernet (PoE) equipment used with COLLABORATE® Versa Lite CT must meet the IEEE 802.3af or 802.3at
standards.
You should use the PoE Power Injector provided with Versa Lite CT. Other power source equipment may immediately ap-
ply power and could damage the Versa Lite CT components.