INSTALLATION MANUAL 8
6. Click on the
Filter Tab
.
7. Add 3 filters
Filter 1 is a PEQ filter with the center frequency at 100 Hz with a gain of 5 dB and
a Q of 0.40
Filter 2 is a PEQ filter with the center frequency at 4000 Hz with a gain of -2 dB and
a Q of 0.27
Filter 3 is a Low Pass filter set at 12000 Hz
8. Other settings in the microphone channel can be set or adjusted based on your application.
9. Repeat these steps for the other Ceiling Microphone Array inputs.