Clearblue CONNECTED Скачать руководство пользователя страница 2

Further information

Holder symbols – how you connect

Holder symbols – error and other symbols

• This test works differently to other ovulation tests which detect one hormone.  

This test detects 

2 key fertility hormones

 – estrogen and luteinizing hormone (LH).  

It’s important for the test to establish ‘baseline’ levels of these hormones so start testing 

as advised and keep testing with the same holder until you see Peak Fertility.  

• If there’s no significant rise above the baseline level of hormones Low Fertility is 

displayed.  You may see a number of Low Fertility days before you see High or Peak 

Fertility.  

• Estrogen rises in the days before the LH surge and prepares your body for ovulation.  

When an estrogen rise is detected High Fertility is displayed each day until Peak Fertility 

is detected. 

• High Fertility is indicated as a flashing smiley face.  

• If an estrogen rise isn’t detected, or the estrogen rise and LH surge are close together, you 

may not see High Fertility.

• An LH surge happens about 24-36 hours before an egg is released from an ovary – 

‘ovulation’.  When your LH surge is detected Peak Fertility is displayed and is generally 

displayed 

after

 Low and High Fertility. 

• Peak Fertility is displayed as a static smiley face (

it does not flash

) and stays on the 

display constantly for 48 hours.  If your LH surge is detected on the first day of testing 

Peak Fertility will be displayed.  

• You may not see Low, High and Peak Fertility days every cycle.  This is not unusual.  

Refer to Questions and Answers for more information.  

• 

Have sex on High and Peak Fertility days to maximize your chances of getting pregnant.  

Questions and Answers

Limits of the test

What happens if I don’t use the first urine after my longest sleep?

You may get unexpected High Fertility results. Test as soon as you can but drink normally.

How accurate is Clearblue® Connected Ovulation Test System?

A laboratory study has shown the test to be over 99% accurate in detecting the LH surge 
(Peak Fertility).* 

I’ve not seen any High Fertility days. Why is this?

It may be that the estrogen level is not high enough to be detected, or your hormone 
changes occur close together, or you started testing too late.  You may still see Peak 
Fertility and you can rely on these results.  

I’ve not seen any Peak Fertility days. Why is this?

Your LH surge may be too low to be detected, or you may not have ovulated this cycle. 
This is not unusual but we recommend you see your doctor if you do not see Peak 
Fertility for 3 consecutive cycles.
If you miss a test around your LH surge you may not see Peak Fertility so remember to 
test as advised, and use the same holder throughout your cycle.

Can any medication or medical conditions affect the result?

Always read the manufacturer’s instructions for any medication that you are taking 
before testing. Certain medical conditions and medications can give misleading results, 
for example if you are pregnant, or have recently been pregnant, have reached 
menopause, have impaired liver or kidney function, have polycystic ovarian syndrome, 
are taking fertility drugs containing luteinizing hormone or human Chorionic 
Gonadotrophin, or are taking antibiotics containing tetracyclines.
Some fertility treatments such as clomiphene citrate may give misleading High Fertility 
results. Peak Fertility results should be unaffected. 
If you do get unexpected results you should discuss them with your doctor.
If you have recently been pregnant you should wait until you have had 2 cycles before 
testing. 
If you have recently stopped using hormonal contraception your cycles may be irregular 
so you may wish to wait until you have had 2 cycles before testing.  
Please check with your doctor if you are taking any medication or have any medical 
condition before planning a pregnancy.  If you have a medically diagnosed fertility 
problem you should ask your doctor if Clearblue® Connected Ovulation Test System is 
suitable for you.

How do I recycle the battery and dispose of the holder?

If you remove the battery from the holder you will not be able to use it again.  

When you have finished using the holder and synced all your results, separate the upper 
and lower halves starting at the end nearest the display. Remove the battery from under 
the central metal cover, and dispose of them according to the appropriate recycling 
protocol. 

Caution:

 Do not take apart, recharge, or dispose of the battery in fire. Do not 

swallow. Keep away from children. Dispose of the rest of the holder according to the 
appropriate recycling protocol for electrical equipment. Do not dispose of electrical 
equipment in fire.

Are test sticks available separately?

No.  If you have used all the test sticks in the pack you will need to buy a new pack 
containing a holder and test sticks.  Use the same holder throughout your cycle with new 
test sticks.
If you have any test sticks left at the end of testing, you can use these and the holder for 
your next cycle if needed.  

I’ve used Clearblue® Connected Ovulation Test System for several months and haven’t 
become pregnant. Why is this?

It can take normal healthy couples many months to achieve a pregnancy. We recommend 
you see your doctor if you are under 35 years and haven’t become pregnant after trying 
for 12 months.  If you are over 35 years you should see your doctor after trying for 
6 months, and if you are over 40 years see your doctor straight away.

As prenatal care is very important for a baby’s health, we recommend that you consult 
your doctor before you try to conceive.   

*The sensitivity of the LH detection in Clearblue® Connected Ovulation Test System is 

40mIU/ml measured against the Third International Standard for urinary LH and FSH for 
Bioassay (71/264).

Made in PRC.  Packaged in USA.

Distributed by Procter & Gamble, Cincinnati, OH 45202.  Manufactured for SPD Swiss 
Precision Diagnostics GmbH (SPD), Route de Saint-Georges 47, 1213 Petit-Lancy, 
Geneva, Switzerland.

Clearblue is a trademark of SPD.  ©2017 SPD. All rights reserved.

Pat. – see www.swissprecisiondiagnostics.com/patents

Android, Google Play and the Google Play logo are trademarks of Google Inc.

Apple, the Apple logo and iPhone are trademarks of Apple Inc., registered in the U.S. 
and other countries. App Store is a service mark of Apple Inc., registered in the U.S. 
and other countries.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, 
Inc. and any use of such marks by Clearblue® is under license. Other trademarks and trade 
names are those of their respective owners.

For self-testing at home.   For 

in vitro

 diagnostic use only.   Not for contraceptive use.  

Not for internal use.  Do not reuse test sticks.   Keep out of reach of children.  
Store between 36° – 86°F.  Bring to room temperature for 30 minutes if refrigerated. 
Do not use if the foil wrapper containing the test stick is damaged.  Do not use a test 
stick after the ‘use by’ date.   

Only use test sticks for Clearblue® Connected with the holder.  

Results must be read on the display and not by any lines you might see on the test stick.  

Certain medical conditions may or may not affect the reliability of this test in predicting 
ovulation. These can include pregnancy, post-partum, menopause symptoms, birth 
control pills, some fertility medications and polycystic ovarian syndrome (PCOS). Women 
with medically diagnosed fertility problems should ask their health care professional if the 
product is suitable for them.  

This device complies with part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) This device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation.

The EMC countermeasures employed within the electronic instrument will provide 
reasonable protection against electromagnetic interference effects likely to be 
encountered in the home environment. Do not use this instrument in close proximity to 
sources of strong electromagnetic radiation as these may interfere with the proper 
operation.

Changes or modifications not expressly approved by the Grantee will void the authority 
to operate this equipment.

This device should not be used in locations where cellular telephone and other electronic 
devices are prohibited, e.g. aircraft and hospitals. 

This device contains a 2.4GHz ISM band transceiver, maximum output power +10dBm.

Bluetooth® SMART wireless technology.

Bluetooth® symbol

Bluetooth® on your holder is turned on. 

The test stick has been ejected too soon.  

Re-insert it quickly. 

An error has occurred during testing. Test again using a new test stick. 

If you have collected urine, use this to test again as soon as the 

display is blank. Otherwise test as soon as you can but drink normally 

and don’t urinate for 4 hours before testing again.

You cannot use this holder again, but you can use any unused test 

sticks.  Test again using another holder from a new pack, following the 

instructions carefully.  

When you insert a test stick, if the display remains blank, you may not 

have inserted it correctly.  Eject the test stick and start again from step 

4.  If the test stick is inserted correctly and the display is still blank, the 

holder is no longer working and you will need to buy a new pack.  
If the display is blank after testing it may be that the holder has 

gotten very wet and it is no longer working.    

This appears when you insert a test stick for first time.  It will also 

appear if you are testing after you have seen Peak Fertility, or if you 

have not taken a test for 3 or more days in a row.  If you miss 

3 or more tests and have not seen Peak Fertility it’s better to wait 

for your next cycle before testing again.  

Bluetooth® symbol and asterisk

When both these symbols are shown, data on the holder is ready to 

sync providing Bluetooth® on your phone is turned on.

Flashing asterisk

The asterisk will flash slowly to show you have data on the holder to 

sync.  When Bluetooth® is turned on this will happen automatically 

providing Bluetooth on your phone is turned on.   You can turn on 

Bluetooth® by inserting the wake-up stick, or it will automatically turn 

on when you have taken your next test.  Remember to eject the 

wake-up stick once the data has been synced.  When completed the 

asterisk will no longer be displayed.    

A symbol will be displayed within 10 minutes if an error has occurred.  

P/N 506007-11  07-2017

A

B

E

C

D

1

2

3

4

5

6

7

8

Find us on:

Clearblue® 

Helpline Monday-Friday 8:30 a.m. - 5:00 p.m. Eastern Time. 

Toll-free.

 1-800-321-3279

Please have the lot numbers          from both the outer and inner packaging. 
Calls are recorded for training and quality control. 

facebook.com/clearblue

www.clearblueeasy.com

Отзывы: