303.872.4477 [email protected] clearcomfort.com
Prior to installation, a site survey should be performed to validate that
the correct system parameters are in place and ready for installation. We
recommend that you maintain compliance within the following operating
ranges for well constructed and circulated spas.
PLEASE NOTE: Installation must be performed by your professional
service provider.
• Spa volume:
All volumes with less than 35 GPM (gallons per
minute).
• Type of spa filter:
Any ANSI 50 approved filtration.
• Pump:
Sufficient to provide venturi air suction. If not possible,
contact Clear Comfort to order a Booster Air Pump Kit.
• Voltage of power supply:
120V or 230V AC.
• Maximum distance from injection point:
Air tubing length should
be as short as possible with no more than 10 feet from the system
to the venturi injector.
• Indoors or outdoors:
Either is suitable. Install away from upward
facing sprinklers is recommended.
• Water quality at installation:
The water quality should be
balanced prior to installing the Clear Comfort system.
CLEAR COMFORT CCW50 EQUIPMENT LIST
1. Air Check Valve
2. 10’ Tubing
3. Flow Meter & Barbed Connector
4. Outlet Box & Lid
5. Conduit Connector
RECOMMENDED MATERIALS AND TOOLS
1. If needed, Clear Comfort’s Booster Air Pump Kit.
2. A power drill and proper hardware for mounting the Clear
Comfort system.
3. Proper plumbing materials and tools for venturi injector
installation. See page 12 for detailed parts list.
7
INSTALLING THE CLEAR COMFORT
SYSTEM